Technical Data; General Technical Data - Siemens SIPART PS2 PA 6DR55 Series Operating Instructions Manual

Electropneumatic positioner
Table of Contents

Advertisement

Technical data

14.1

General technical data

SIPART PS2 (all versions)
General data
Range of stroke (linear actuator)
Angle of rotation (part-turn actuator)
Installation
On the linear actuator
On the part-turn actuator
Control unit
Five-point controller
Dead zone
dEbA = auto
dEbA = 0.1 ... 10 %
Analog-to-digital converter
Scanning time
Resolution
Transmission error
Temperature influence
Cycle time
20 mA/HART device
PA device
FF device
Binary input BE1 (clamp 9/10; galvanically connected with
basic device)
Degree of protection
)
1
SIPART PS2 with PROFIBUS communication
Operating Instructions, 09/2007, A5E00127926-07
3 ... 130 mm (0.12 ... 5.12") (angle of rotation of the
feedback shaft 16 ... 90°)
30 ... 100°
Using the mounting kit 6DR4004-8V and, if required, an
additional lever arm 6DR4004-8L on the actuators as per
IEC 534-6 (NAMUR) with a fin, columns, or a plane
surface
Using the mounting kit 6DR4004-8D on the actuators with
fastening plane as per VDI/VDE 3845 and DIN 3337: The
required mount must be provided on the actuator-side;
shaft with groove, and M6 female thread.
Adaptive
Adaptive or can be preset
Adaptive or can be preset
10 ms
≤ 0,05 %
≤ 0,2 %
≤ 0.1 %/10 K (≤ 0.1 %/18 °F)
20 ms
60 ms
60 ms (min. loop time)
Only usable for a dry contact; max. contact load <5 mA at
3 V
IP66 according to EN 60529 / NEMA 4X