Grease Service Life And Fill Quantities - Siemens SIMOTICS XP 1MD4 Operating Instructions And Installation Instructions

Induction motor
Table of Contents

Advertisement

Maintenance
9.1 Inspection and maintenance
9.1.7.4

Grease service life and fill quantities

Standard roller bearings
Size
Grease stability time for permanent lubrication or relubrication in‐
for a regreasing system in operating hours at rated speed
Horizontal type of construction
3000
rpm
71
80
90
33000
100
112
132
160
180
200
225
24000
250
280
315
4000
355
The specified grease stability times and/or relubrication intervals are valid for maximum
ambient temperatures of 40 °C. Reduce the lubrication interval for a 10 °C increase in
temperature by a factor of 0.7 of the value listed in the table (max. 20 °C = factor 0.5). With an
ambient temperature <= 25° C, twice the grease stability time can be expected; but a maximum
of 40000 hours. Times for operation on 60 Hz systems on request. With pure coupling operation
with flexible coupling, the calculated bearing life is L10h greater than 50000 hours. Comply
with the grease service life and relubrication intervals.
82
terval
Vertical type of construction (V)
(B)
1500
≤1000
3000
rpm
rpm
rpm
24000
40000
40000
16000
8000
11000
2800
Grease filling quantity for permanent
lubrication or grease quantity for relubrica‐
Permanent lubrica‐
1500
≤1000
3000
rpm
rpm
rpm
33000
18
32
51
40000
63
79
26000
99
99
5600
8000
4000
5600
tion in g per bearing
Relubrication
tion
≤1500
3000
rpm
rpm
3
3
-
3
3
-
4
4
-
9
9
-
9
9
-
18
-
32
-
51
-
63
-
79
-
99
-
132
-
-
-
35
-
-
35
SIMOTICS XP 1MD4/1MD5
Operating Instructions 05/2015
≤1500
rpm
-
-
-
-
-
-
-
-
-
-
-
-
25
50

Advertisement