6.5 Binding underfloor heating controller HCE80 or HCC80

NOTE
A underfloor heating controller can be assigned to a room only if a set
value adjuster or a room sensor has been previously assigned to the
room.
1. Press and hold the Bind button
controller until the LED of the corresponding room (zone) flashes.
2. The LED of the room will flash with a GREEN light.
3. Click on the Continue button on the SRC-10.
4. If the binding process is successful, then the yellow LED of the
underfloor heating controller will light up.
5. Room binding is complete.
In order to connect further rooms, repeat the process:
1. Press the Bind button
twice (skip flashing red LED).
The green LED of the next room will flash.