Quasar HQ-2101RH Install And Operation Instructions

Quasar room air conditioner operation's manual hq-2101rh hq-2121rh

Advertisement

Quick Links

Please read these operating instructions thoroughly before
using your air conditioner and keep them for future reference.
For assistance, please call: 1-800-211-PANA (7262) or send e-mail to
consumerproducts@panasonic.com or refer to www.panasonic.com
INSTALLATION AND

OPERATING INSTRUCTIONS

Room Air Conditioner

HQ-2101RH
Model
HQ-2121RH
ENGLISH
ESPAÑOL
F563185

Advertisement

Table of Contents
loading

Summary of Contents for Quasar HQ-2101RH

  • Page 1: Room Air Conditioner

    Please read these operating instructions thoroughly before using your air conditioner and keep them for future reference. For assistance, please call: 1-800-211-PANA (7262) or send e-mail to consumerproducts@panasonic.com or refer to www.panasonic.com INSTALLATION AND OPERATING INSTRUCTIONS Room Air Conditioner HQ-2101RH...
  • Page 2 Thank you for purchasing a Quasar product. Gracias por comprar un producto Quasar. This Quasar Room Air Conditioner has been designed for maximum energy efficiency and minimal noise while Este Acondicionador De Aire Quasar ha sido diseñado para mantener la habitación a una temperatura comfortable con máxima eficiencia de energia y mínimo ruido.
  • Page 3: Table Of Contents

    CONTENTS CONTENIDO CONTENIDO SAFETY PRECAUTIONS ... 2 ~ 5 PRECAUCIONES DE SEGURIDAD AIR CONDITIONER INSTALLATION ... 6 ~ 11 INSTALACIÓN DEL ACONDICIONADOR DE AIRE PART IDENTIFICATION ... 12 ~ 13 IDENTIFICACIÓN DE LOS COMPONENTES AIR CONDITIONER OPERATION ... 14 OPERACIÓN DEL ACONDICIONADOR DE AIRE ENERGY SAVING HINTS ...
  • Page 4: Safety Precautions

    PRECAUCIONES DE SEGURIDAD PRECAUCIONES DE SEGURIDAD • Please observe the following safety precautions when using your air conditioner. Failure or negligence in observing these safety precautions could cause fire, electrical shock or personal injury. • Por favor observe las siguientes precauciones de seguridad cuando use su acondicionador de aire.
  • Page 5: Operation Precautions

    OPERATION PRECAUTIONS PRECAUCIONES DE OPERACIÓN WARNING This sign warns of risk of death or serious injury. Esta señal indica riesgo de peligro de muerte o lesiones serias. ADVERTENCIA • Do not modify the length of the power cord or use an extension cord. •...
  • Page 6 PRECAUCIONES DE SEGURIDAD PRECAUCIONES DE SEGURIDAD CAUTION CUIDADO • Switch off the breaker and remove the power plug from the socket if the unit will not be operated for a long period, such as while on vacation. • Apague el interruptor y quite el enchufe principal, si no utilizará la unidad por un largo tiempo, como durante las vacaciones.
  • Page 7 This sign warns of injury or damage to property. CAUTION CUIDADO Esta señal indica peligro de lesiones o daño a la propiedad. • Ventilate the room occasionally where the unit is installed. • Ventile ocasionalmente el cuarto donde la unidad esta instalada. Since windows are kept closed, it does good to open them periodically to ventilate the room.
  • Page 8 AIR CONDITIONER INSTALLATION AIR CONDITIONER INSTALLATION INSTALACIÓN DEL ACONDICIONADOR DE AIRE INSTALACIÓN DEL ACONDICIONADOR DE AIRE CAUTION CUIDADO Please remove the shipping blocks fixed to the compressor and front grille before installation. Por favor remueva los tacos de envío fijados en el compresor y la rejilla frontal antes de la instalación.
  • Page 9: Select The Best Location

    NOTA: Esta unidad tambíen se puede instalar a través de la pared. En este caso, se deberán realizar trabajos de carpintería y construir una estructura en la abertura deacuerdo con los reglamentos locales. PREPARATION OF AIR CONDITIONER CHASSIS PREPARACIÓN DEL CHASIS DEL ACONDICIONADOR DE AIRE Remove the front intake grille Quite la rejilla frontal de la toma de aire Pull up the front intake grille about 90°...
  • Page 10: Air Conditioner Installation

    AIR CONDITIONER INSTALLATION AIR CONDITIONER INSTALLATION INSTALACIÓN DEL ACONDICIONADOR DE AIRE INSTALACIÓN DEL ACONDICIONADOR DE AIRE Remove the front grille Quite la rejilla frontal Remove the adhesive tapes from all sides of the front grille. Open the control panel cover.
  • Page 11: Cabinet Installation

    CABINET INSTALLATION INSTALACIÓN DEL CAJA Cut the “Sealing Ribbon” to the proper length, and attach it along the bottom edge of the bottom window sash. Corte la cinta de sellar del largo apropiado y colóquela a lo largo de la parte inferior de la ventana de guillotina. To prevent condensation water from dripping inside,the cabinet should be installed level or very slightly tilted to the outside.
  • Page 12 AIR CONDITIONER INSTALLATION AIR CONDITIONER INSTALLATION INSTALACIÓN DEL ACONDICIONADOR DE AIRE INSTALACIÓN DEL ACONDICIONADOR DE AIRE Reinstall the chassis locking brackets and retighten the screws Reinstale las ménsulas de retención del chasis y apriete bien los tornillos INSTALLATION OF THE FRONT GRILLE INSTALACIÓN DE LA REJILLA FRONTAL...
  • Page 13 COMO INSTALAR LA BANDEJA DE DRENAJE (OPCIONAL) Condensed water drainage Drenaje de agua condensada This air conditioner employs a “Slinger-Up System” which is designed to splash the condensed water on the condenser coil for maximum cooling efficiency, thus producing a splashing sound.
  • Page 14: Part Identification

    IDENTIFICACIÓN DE LOS COMPONENTES IDENTIFICACIÓN DE LOS COMPONENTES MAIN UNIT UNIDAD PRINCIPAL Air filter (behind the front intake grille) Filtro de aire (detras de la rejilla frontal de toma de aire) Front intake grille Rejilla frontal de toma de aire Airflow Direction Vane Vertical Airflow Direction Adjustment Up-and-Down The vertical airflow direction vane is controlled by positioning the vane to discharge...
  • Page 15 VENTILATION LEVER PALANCA DE VENTILACIÓN When the slide lever is in the : Cuando la palanca se encuentra deslizada en la: – “OPEN” position, the ventilation door opens to allow air, smoke or odors to be expelled from the room. –...
  • Page 16: Air Conditioner Operation

    AIR CONDITIONER OPERATION AIR CONDITIONER OPERATION OPERACIÓN DEL ACONDICIONADOR DE AIRE OPERACIÓN DEL ACONDICIONADOR DE AIRE AIR SWING HIGH COOL HIGH COOL HIGH COOL HIGH COOL THERMOSTAT NOTE : Recommended setting NOTA : Nivel recomendado AIR SWING 1. Open the control panel cover 1.
  • Page 17: Energy Saving Hints

    Evite calentamiento. Proper capacity of the room The cooling capacity of the room air conditioner must match the room size for efficient and satisfactory operation. Capacidad apropiada en la habitación...
  • Page 18: Care And Maintenance

    CUIDADO Y MANTENIMIENTO CUIDADO Y MANTENIMIENTO Always turn off the air conditioner and the main power supply before unplugging the power cord to clean the unit. Switch off the power supply if the unit is not going to be used for a long period of time.
  • Page 19: Air Filter Removal

    INFORMACIÓN ÚTIL If the air filter becomes clogged with dust, the cooling capacity will drop, and 6% of the electricity used to operate the air conditioner will be wasted. Si el filtro de aire llega a ser atascado con el polvo, la capacidad de enfriamiento disminuirá,...
  • Page 20: Care And Maintenance

    CUIDADO Y MANTENIMIENTO CUIDADO Y MANTENIMIENTO Pre-season Inspection Inspección pre-estación • Is the discharged air cold? After 15 minutes of operation, it is normal for the temperature difference between intake and outlet air to be more than 14.4°F. • Esta descargado el aire frío? La operación es normal si la diferencia de temperatura entre el aire que entra y el que sale es 14,4°F o más, después de 15 minutos de la operación de enfriamiento.
  • Page 21: Product Specification

    Profundidad NET WEIGHT PESO NETO GROSS WEIGHT PESO BRUTO * Specifications are subject to change without notice for further improvement. * Las especificaciones están sujetas a cambios por mejoras sin previo aviso. HQ-2101RH 10,000 Btu/h 10.000 Single Monofásico (Hz) (Amps) 10.5...
  • Page 22: Before Calling For Service

    BEFORE CALLING FOR SERVICE BEFORE CALLING FOR SERVICE ANTES DE LLAMAR PARA MANTENIMIENTO ANTES DE LLAMAR PARA MANTENIMIENTO BEFORE ANTES If the unit is noisy during operation. Si la unidad está demasiado ruidoso durante el funcionamiento. Humm… Sssssss… KACK! POSSIBLE CAUSES OF THE ABOVE PROBLEMS POSIBLES CAUSAS DE LOS PROBLEMAS ARRIBA MENCIONADOS Condition Condición...
  • Page 23 • The main power cord is not plugged in. Condition • The internal fuse has blown. Condición • The house circuit breaker has tripped. • El cable de alimentación no está enchufado. • El fusible interno se ha quemado. • El interruptor de circuitos de la casaha disparado. •...
  • Page 24: Limited Warranty

    One Panasonic Way Secaucus, New Jersey 07094 Quasar Room Air Conditioner Panasonic Consumer Electronics Company or Panasonic Sales Company (collectively referred to as “the Warrantor”) will repair this product with new or refurbished parts in case of defects in material or workmanship, free of charge, in the USA or Puerto Rico in accordance to the following (All time periods start from the date of the original purchase).

This manual is also suitable for:

Hq-2121rh

Table of Contents