Electrical Requirements; Gas Requirements - Whirlpool 3XWGD5705 Installation Instructions Manual

Hide thumbs Also See for 3XWGD5705:
Table of Contents

Advertisement

Available languages

Available languages

Electrical Requirements

IMPORTANT: Observe all governing codes and ordinances.
This dryer is supplied/fitted with an electricity supply cord and
plug. It should be connected to electricity supply socket at the
voltage shown on the rating plate. The minimum supply fuse
capacity should be 5A. The dryer must be positioned so that the
plug is accessible. If the fitted plug is not used, the electrical
connection must be carried out by a competent electrician in
accordance with local or national codes.
If the supply cord is damaged, it must be replaced with a
specially terminated cord by an authorized service agent or a
similarly competent person.
Do not use an adapter.
Do not use an extension cord.
If codes permit and an additional earth bond wire is used, it is
recommended that a qualified electrician determine that the earth
bond, path is adequate.
NOTE: In accordance with the European EMC directive
(89/336/EEC), the maximum electricity supply system impedance
to which the electric dryer should be connected is declared to be
0.29 Ohm + j0.180 Ohm.
6

Gas Requirements

OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Gas supply:
Check that dryer is equipped with the correct burner for the
particular type of gas supply. Burner information will be found on
the model/serial rating plate in the door well of the dryer. If this
information does not agree with the type of gas available, see
your dealer.
Natural Gas:
This dryer is factory adjusted for use with NATURAL GAS (G20),
and no further adjustment should be required at installation.
L.P. Gas:
This dryer is also certified for use with L.P. (propane or butane)
gases with appropriate conversion. No attempt shall be made to
convert the appliance from the gas specified on the model/serial
rating plate for use with a different gas without consulting the
serving gas supplier.
Conversion must be done by a competent service technician.
Gas conversion kit, part number 279918, is available for
purchase from your dealer. Full instructions are supplied with the
kit.