SPECIFICATIONS
Model
Suffix AD:
atmospheric, direct burner ignition
Suffix BD:
as AD but with flame relay output
Suffix CD:
fan assisted, direct burner ignition
Suffix DD:
as CD but with flame relay output
Suffix PD:
as AD except volatile lock-out
Suffix QD:
as BD except volatile lock-out
Suffix RD:
as CD except volatile lock-out
Suffix TD:
as DD except volatile lock-out
Supply voltage
220 ... 240 Vac, 50/60Hz (-15%, +10%)
Power consumption
4 VA
Humidity
90% RH max. at 40°C non condensing
Storage
- 30 ... 70°C
Ambient temperature
-15 ... 60°C
Electrical rating (see also note 10.)
Alarm:
220 ... 240 Vac, 50/60Hz, 1 A,
cos ϕ > 0.6 or max 1 mA
Fan:
220 ... 240 Vac, 50/60Hz, 1 A,
cos ϕ > 0.6
Flame relay contact: 220 ... 240 Vac, 50/60Hz,1 A,
cos ϕ > 0.6
Flame opto coupler: +5 V, 10 kΩ
LPG valve:
220 ... 240 Vac, 50/60 Hz, 1 A max,
cos ϕ > 0.6
Electrical connection
High voltage spark: 2.8 x 0.5 mm spade terminal
Flame sensing:
4.8 x 0.8 mm spade terminal
PCB connectors:
Molex 3003 series suitable for
Molex 3001 female cable connector
EN2R-9031 0402R15-NE
S4565AD, BD, CD, DD, PD, QD, RD, TD "1000" SERIES
Housing (degree of protection)
See:
Timing (depending on O.S. number)
Self check time (T
Waiting time (T
Safety time (T
Extended spark ignition time:
Flame sensing
Min flame current:
Response time on:
Response time off (T
Ignition
Spark voltage:
Spark energy:
Repetition rate:
Max. spark gap:
Optional external ignition circuit:220 ... 240 V (at no load),
Length flame sensing cable
1 m max.
Length ignition cable
0.5 m max.
Length of wiring for external components
1 m max.
Remark
Optional integrated flame relay available with safe separation
or opto coupler with safe separation.
N.C. contact of flame relay has no safe separation.
18
accessories for degree of protection page 7..
replacement parts and accessories page 66..
):
c
):
w
):
s
(depending on elaps of safety time)
):
FR
WARNING
Opto coupler interface needs a debounce time > 20
ms in order to prevent noise caused by transients on
mains.
1.5 s
0 ... 30 s
3.5 ... 25 s
0 ... T
s
0.9 µA
> 0.2 s
< 1 s
> 12 kV at 40 pF load
(depending on O.S. number)
3 ... 15 µAs
2.5 ... 60 Hz
(depending on O.S. number)
3.5 mm
single phase rectified,
max 2 VA