Cisco Mds 9500: Guidelines And Limitations - Cisco Nexus 7000 series Configuration Manual

Nx-os fcoe
Hide thumbs Also See for Nexus 7000 series:
Table of Contents

Advertisement

Guidelines and Limitations
For more information about VDC, see the Cisco Nexus 7000 Series NX-OS Virtual Device Context Configuration
Guide.

Cisco MDS 9500: Guidelines and Limitations

• You cannot enable FCoE on the default VLAN.
• You can only enable FCoE on an FCoE module.
• The QoS policy must be the same on all Cisco FCoE switches in the network.
• Cisco MDS 9500 does not support LAN traffic and only accepts and processes FCoE frames.
• You must install a Supervisor-2A module to configure FCoE.
• You can install an FCoE module in a fabric that uses FC-Redirect services but do not install the FCoE
• SME does not support any FCoE connected devices including devices connected through the MDS FCoE
• In Cisco MDS NX-OS Release 5.2(x), you cannot install a FCoE module in a switch that is running
OL-25809-02
module in the same switch where FC-Redirect services application modules are enabled.
linecard (DX-X9708-K9)
DMM, SME, or IOA.
Cisco MDS 9500: Guidelines and Limitations
Cisco NX-OS FCoE Configuration Guide for Nexus 7000 and MDS 9500
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds 9500 series

Table of Contents