Guidelines And Limitations; Cisco Nexus 7000: Guidelines And Limitations - Cisco Nexus 7000 series Configuration Manual

Nx-os fcoe
Hide thumbs Also See for Nexus 7000 series:
Table of Contents

Advertisement

Configuring FCoE VLANs and Virtual Interfaces

Guidelines and Limitations

Cisco Nexus 7000: Guidelines and Limitations

• You cannot enable FCoE on default VLAN.
• The QoS policy must be the same on all Cisco FCoE switches in the network.
• Beginning with Cisco NX-OS Release 6.1, FCoE is supported on F2 and F2e Series modules.
FCoE VDC
FCoE in a dedicated storage VDC has the following guidelines:
• Enable the FCoE feature set in only one VDC.
• Create VLANs in the FCoE allocated VLAN range.
• Do not enable any other features other than storage-related features in the dedicated FCoE VDC.
• Allocate resources for the dedicated FCoE VDC from an F Series module, such as the 32-port 1- and
• Rollback is not supported in a storage VDC.
• FCoE support on F2 and F2e Series modules, SF248XP-25 requires Supervisor 2 module.
• F2 and F2e series modules cannot exist in the same VDC with any other module type. This applies to
Shared Interfaces
Any change in protocol state that flaps the parent port of a shared interface because of any port feature
Note
also affects the FCOE traffic on the storage vdc.
The following interface config modes are not allowed while sharing an interface from Ethernet vdc to a storage
vdc:
• SPAN destination
• Private VLAN mode
• Port-channel interfaces
• Access mode
• mac-packet-classify
• Interfaces that are part of a VLAN that has an associated QoS policy
OL-25809-02
◦ FCoE supports only F2e (SFP+) modules.
◦ FCoE does not support F2e (Copper) modules.
10-Gigabit Ethernet I/O module (PID N7K-F132XP-15) .
both LAN and storage VDCs.
Cisco NX-OS FCoE Configuration Guide for Nexus 7000 and MDS 9500

Guidelines and Limitations

23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds 9500 series

Table of Contents