Page 2
Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene.
Page 3
450 / 660 / 940 Fig. 1 min 100 min 100 min 100 Fig. 2: Minimum distance...
Mounting with wall bracket Possibility to use guide holes for easy positioning 10 cm Align the wall bracket Fig. 3: Mounting wall bracket Fig. 4: Fastening with lockplate...
Mounting when a connection box is to be placed behind the unit PFS4/10/17 - 214/434/712 Fig. 5: Free space to mount the connection box behind the unit Fig. 6: Bending the wall bracket Portable use Fig. 7: Floor stand...
Page 6
Fig. 8: Open the unit DISPLAY BOARD 12VDC 90°C Jumper 60/90°C 60°C RF In OUTLET SENSOR Overheat protection Fig. 9: Changing the maximum surface temperature from 90 °C to 60 °C by removing the jumper. Default 90 °C. POWER BOARD 230/400V 12VDC PFSE/D4...
Page 9
(buttons, switches, etc.) are within 3. Fasten the stand to the unit with screws reach of persons in baths or showers. included, in intended holes, PFSE4 1x, Convectors for portable use must not be PFSE10/17 2x. used close to pools, bathtubs or showers.
Page 10
Switching surface temperature 60 / 90 °C Overheat protection On delivery, max. surface temperature is The fan convector is equipped with overheat set to 90 °C. To select the lower surface protection. The overheat protection resets by temperature - max 60 °C, remove the jumper turning off the unit during 10 minutes.
Page 11
Control The fan convector has a digital display on which all settings are made and can also be remotely controlled via an app (iOS, Android) or web browser. Start up Home screen and keypad Keypad 1 Increase / up 2 Decrease / down 3 User menu / browse / proceed 4 Return 5 Confirm / select...
Display symbols Comfort mode Fan on Reduced (night mode) Fan off. Flashes Frost protection when cooling. Symbol flashing Fan Auto mode Timer on Week program on Active fan steps Weekday: 1 = Mon to 7 = Sun Symbol flashing Sending/reception °C Symbol flashing Heat on...
Fan mode The fan speed can be set to suit any Fan mode Functions requirements. Modes: Auto/Low/High/Off. Auto The fan runs at low speed except: - when the room temperature is more than 2 °C below the set point, User menu then the fan speed increases to high speed for a shorter heating Select...
Timer Week program PFS has nine preset week programs (P1 to P9) The set temperature can be changed for a limited time with the timer (1 hour to 45 and the possibility to add four (U1-U4). days). The fan runs on the set value. The function ITCS (default) makes the control learn when it needs to start in order to reach a certain desired temperature at a...
Page 15
Setting week programs Select the start time for the selected mode (Reduced/Comfort). User menu Select Confirm P1 or the recently used program is shown. Select between Reduced mode or Comfort mode for following time. Confirm Confirm Selecting a preset program P1 - P9 Select the start time for the selected mode (Reduced/Comfort).
Settings Power failure Note! A power loss longer than 12 hours may require an adjustment of time and date. The User menu week program is affected if the clock is not Select correctly set. Confirm Browse the menu options. Confirm Default Description Menu...
The function with fans off at reduced Put FRT function to OFF in Settings. mode (FRT) is active. Check the fan motor connections. The quick plug for the first motor is de- tached. If the problems continue, please contact Frico for support.
Page 19
Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...