Changing The Parameter Setting Value; Operation Display - Mitsubishi Electric FR-D700 Instruction Manual

Hide thumbs

Advertisement

Operation panel
1.2.3

Changing the parameter setting value

Changing
Change the Pr. 1 Maximum frequency setting.
example
1.
Screen at power-ON
The monitor display appears.
2.
Press
to choose the PU operation mode.
3.
Press
to choose the parameter setting
mode.
4.
Turn
until
5.
Press
to read the present set value.
"
"(120.0Hz (initial value)) appears.
6.
Turn
to change the set value to
"
" (60.00Hz).
7.
Press
to set.
REMARKS
to
appears .................... Write disable error
appears .................... Write error during operation
appears .................... Calibration error
appears .................... Mode designation error
(For details,
refer to the Instruction Manual (Applied).)
The number of digits displayed on the operation panel is four. Only the upper four digits of values can be displayed and set. If the
values to be displayed have five digits or more including decimal places, the fifth or later numerals cannot be displayed nor set.
(Example) For Pr. 1
When 60Hz is set, 60.00 is displayed.
When 120Hz is set, 120.0 is displayed and second decimal place is not displayed nor set.
4
Operation
(Pr. 1) appears.
Turn
to read another parameter.
Press
to show the setting again.
Press
twice to show the next parameter.
Press
twice to return to frequency monitor.
is displayed...Why?
PU indicator is lit.
PRM indicator is lit.
(The parameter number read previously
appears.)
Flicker...Parameter setting complete!!
Display
Hz
A
Hz
A
Hz
A