Download  Print this page

Collision Prevention Override; Intelligent Collision Protection - Philips Azurion Instructions For Use Manual

Hide thumbs
   
1
2
Table of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402

Advertisement

About the System
The optional Keep Maximum SID function keeps the detector in the maximum SID position, to prevent
it from hitting objects while performing APC movements. Recalling a stand position may cause a
collision. If necessary, stop the recall function and position the stand manually.

3.1.5 Collision Prevention Override

You can override collision prevention function in the following situations.
Smart BodyGuard Override
You can override the BodyGuard function if it is blocking motorized stand movements that may be
caused by equipment used around the patient and table, for example ECG cables. This function is called
Smart BodyGuard Override. It is the responsibility of the operator to ensure that collisions with the
patient or equipment do not occur while the override function is active.
To activate the Smart BodyGuard Override function after a movement is blocked by the BodyGuard,
release the movement switch and reactivate it within 5 seconds.
When you activate the override function, a message is displayed in the status area, and a repeating
beep sound can be heard. The maximum movement speed during override is reduced compared to
normal movements. The override function is deactivated and normal movements are available again if
the requested movement is no longer being limited by the BodyGuard sensor.
NOTE Smart BodyGuard Override is a configurable function and it may not be enabled on every
Table Height Collision Override
If you need to perform CPR, you can override the force sensor that stops table height and tilt
movements.
The table is equipped with a force sensor measuring the force vertically applied to the surface of the
tabletop. Normally the measured force is determined by the patient weight. During motorized
movement, if a collision force exceeding the safety threshold is detected, the movement stops and is
briefly reversed.
To override the force sensor, release the table tilt switch or table height switch and then re-apply the
switch movement within 5 seconds to continue the movement. If no switch movements are performed
within 5 seconds, override mode is deactivated and table movements are stopped.
NOTE There are no audible signals during table height collision override mode.

3.1.6 Intelligent Collision Protection

Intelligent Collision Prevention (iCP) prevents collisions between the tabletop, the X-ray tube, and the
stand. In a biplane system, iCP also prevents collisions between the frontal stand and the lateral stand.
When the distance between the tabletop and stand becomes too small, a collision is prevented by
stopping motorized stand movements (except for motorized detector shift movement).
The iCP function allows you to resume movement and decrease the distance between the table and
stand in a controlled way:
• A small movement step is made when the calculated distance decreases further during the
movement.
• When the calculated distance remains the same during the movement, the movement continues at
reduced speed.
• When the calculated distance increases during the movement, the movement continues at normal
speed.
Azurion Release 1.2 Instructions for Use
system
31
Equipment in the Examination Room
Philips Healthcare 4522 203 52421