Removing The Release Motor Hp Sensor(Sr11); Removing The Document Width Volume(Vr1) - Canon H1 Service Manual

Color image reader unit
Table of Contents

Advertisement

4
Parts Replacement and Cleaning Procedure > Clutch Solenoid Motor Fan PCB (DADF) > Removing the Document Width Volume(VR1)

Removing the Release Motor HP Sensor(SR11)

1) Open the feeder cover.
2) Open the DADF.
3) Detach the front
cover."Removing the Front Cover"(page 4-18).
4) Close the DADF.
5) Remove the release motor HP sensor
- Connector 1 pc
x1
4
Parts Replacement and Cleaning Procedure > Clutch Solenoid Motor Fan PCB (DADF) > Removing the Document Width Volume(VR1)
1) Detach the cover on the reverse side of the document
2) Remove the document width volume unit.
- Connector 2 pcs.
- Screw 2 pcs.
F-4-79
3) Remove the document width volume.
- Hexagon NUT 1pc
- Washer 1 pc
CAUTION:
Install the document width volume with its lower gear groove [1] fitting on the projection
[2] on the document tray side. Be sure to install it with the arrow on the gear aligned
with the arrow [3] on the tray cover.

Removing the Document Width Volume(VR1)

x2
x2
VR1
[2]
4-34
tray.(Refer to page 4-33)
[3]
[2]
[1]
F-4-80
4-34