Error Mode - LG TCW2013LS2 Owner's Manual

Hide thumbs Also See for TCW2013LS2:
Table of Contents

Advertisement

Available languages

Available languages

ERROR MODE

Meaning of Error Codes that LED displays during occurrence of
problem.
Problem
• Water supply is not adequate in area.
• Water supply taps are not completely open.
• Water inlet hose is bent.
• The filter of the inlet hose clogged.
• Drain hose is bent or clogged.
• The drain filter is clogged.
• Load is too small.
• Load is out of balance.
• The appliance has an imbalance detection
• Is the door opened or not completely closed? Close the door completely.
• Door lock is broken.
• The water overfills due to a faulty water
• The water level sensor malfunction.
• Overload in motor.
• Disconnection of card reader cable.
• Too much detergent is used.
• Emergency stop button is pressed.
• Thermistor is opened or shorted.
Possible Cause
and correction system. If individual heavy
articles are loaded (bath mat, bath robe,
etc.) and the imbalance is too great, after
several attempts to restart the spin cycle the
machine will stop and the error code will be
displayed.
valve.
ERROR MODE
Solution
Check another tap in the house.
Fully open tap.
Straighten hose.
Check the filter of the inlet hose.
Clean and straighten the drain
hose.
Clean the drain filter.
Add 1~2 similar items to help
balance the load.
Rearrange load to allow proper
spinning.
✽ If it will not open, call for
service.
Check the door switch.
Close the water tap.
Unplug the power plug.
Call for service.
Restart the cycle after 30 minutes.
If
is not released, call for
service.
Check the card reader wire.
This is not an error. It indicates a
suds removal routine.
It will clear and restart the cycle
when the suds are gone.
Release the emergency button.
Thermistor should be replaced.
75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tcw2013cs2Tcw2013qs2Tcw2013qs1Tcw2013cs1

Table of Contents