Wiring Diagram - Mitsubishi Electric PLFY-P20VEM-E Technical & Service Manual

City multi plfy series split-type, heat pump air conditioners
Hide thumbs Also See for PLFY-P20VEM-E:
Table of Contents

Advertisement

6

WIRING DIAGRAM

PLFY-P20VEM-E.UK
PLFY-P50VEM-E.UK
PLFY-P125VEM-E.UK
SYMBOL
I. B
INDOOR CONTROLLER BOARD
CN27
CONNECTOR DAMPER
CN32
REMOTE SWITCH
CN51
CENTRALLY CONTROL
CN52
REMOTE INDICATION
F1
FUSE (T 6.3AL 250V)
MODE SELECTION
SW1
SWITCH
SW2
CAPACITY CODE
SW3
MODE SELECTION
SW11
ADDRESS SETTING 1s DIGIT
SW12
ADDRESS SETTING 10s DIGIT
SW14
BRANCH NO.
SW21
CEILING HEIGHT
DISCHARGE OUTLET NUMBER
OPTION SELECTOR
SW22
PAIR NO. SETTING
SWE
DRAIN PUMP (TEST MODE)
* Be sure to turn off the source power and
then disconnect fan motor connector.
(Failure to do so will cause trouble in
Fan motor)
MF
MS
3~
I.B
1
4
CNMF
(WH)
+
POWER SUPPLY
~/N 220-240V 50Hz
F1
220V 60Hz
BREAKER
(16A)
FUSE(16A)
3
5
1
BK
RD
PULL
L
BOX
BU
N
TO NEXT
INDOOR UNIT
NOTES:
1. At servicing for outdoor unit, always follow the wiring
diagram of outdoor unit.
2. In case of using MA-Remote controller, please connect
to TB15. (Remote controller wire is non-polar.)
3. In case of using ME-Remote controller, please connect
to TB5. (Transmission line is non-polar.)
4. Symbol [S]of TB5 is the shield wire connection.
5. Symbols used in wiring diagram above are,
: terminal block,
6. The setting of SW2 differs in the capacity and model.
For the detail, refer to the table 1.
7. Make sure to turn off the indoor and the outdoor units
before replacing indoor controller board.
8.
is the switch position.
OCH657
PLFY-P25VEM-E.UK
PLFY-P63VEM-E.UK
NAME
SYMBOL
DP
DRAIN PUMP
FS
DRAIN FLOAT SWITCH
LEV
LINEAR EXPANSION VALVE
MF
FAN MOTOR
MV
VANE MOTOR
TH21
THERMISTOR
TH22
TH23
TB2
TERMINAL
TB5
BLOCK
TB15
W.B
BZ
CNB
LED2 LED1
RU
9
1
SW1
SW2
DP
MS
3~
9
7
3
1
CNP
(WH)
9
1
CN90
(WH)
LED1
SWE
-
OFF
ON
CN4Z
(WH)
4
0 9 8 7 6 5 4 3 2 1
CND
(BK)
1
SW3
I-SEE SENSOR
CORNER PANEL
(OPTION PART)
4
<Table 1> SW2 (CAPACITY CODE)
MODELS
20
25
32
: connector.
LED on indoor board for service
Mark
LED1
LED2
PLFY-P32VEM-E.UK
PLFY-P80VEM-E.UK
OPTION PART
NAME
W.B
BZ
LED1
LED2
RU
SW1
ROOM TEMP. DETECTION
SW2
(0ºC/15kΩ, 25ºC/5.4kΩ)
MT
PIPE TEMP. DETECTION / LIQUID
(0ºC/15kΩ, 25ºC/5.4kΩ)
PIPE TEMP. DETECTION / GAS
(0ºC/15kΩ, 25ºC/5.4kΩ)
POWER SUPPLY
TRANSMISSION
MA-REMOTE CONTROLLER
TH22
FS
TH21
TH23
4
4
1
4
1
2
1
4
1
CN4G
CN4F
CN44
CN20
(BU)
(WH)
(RD)
(WH)
2
1
CN5Y
CN27
(WH)
(RD)
5
1
6 5 4 3 2 1
0 9 8 7 6 5 4 3 2 1
4 3 2 1
OFF
OFF
OFF
ON
ON
ON
SW2
SW1
SW22
Refer to table 1.
I-SEE
M
SENSOR
5
MT
SW2
MODELS
SW2
MODELS
ON
ON
40
80
OFF
OFF
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
50
100
OFF
OFF
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
63
125
OFF
OFF
1 2 3 4 5 6
1 2 3 4 5 6
Meaning
Main Power supply (Indoor unit:220-240V AC)
Main power supply
power on → lamp is lit
Power supply for
Power supply for MA-Remote controller
MA-Remote controller
on → lamp is lit
20
PLFY-P40VEM-E.UK
PLFY-P100VEM-E.UK
PCB FOR WIRELESS REMOTE CONTROLLER
BUZZER
LED (OPERATION INDICATION : GREEN)
LED (PREPARATION FOR HEATING : ORANGE)
RECEIVING UNIT
EMERGENCY OPERATION (HEAT / DOWN)
EMERGENCY OPERATION (COOL / UP)
I-SEE SENSOR MOTOR
AUTOMATIC FILTER
ELEVATION PANEL
1
4
(OPTION PART)
CN4G
LEV
M
6
5
1
5
1
CN51
CN52
(WH)
(GN)
LED2
CN60
(WH)
6
1
1
3
CN32
CNV
(WH)
(WH)
SW11
SW12
SW14
6 5 4 3 2 1
OFF
OFF
ON
ON
19
BRANCH No.
1s DIGIT
10s DIGIT
SW21
SW2
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
Function
TB15
2
1
TB5
S
M2
M1
1
2
20
20
5
5
5
5
M
M
M
M
MV
MV
MV
MV

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents