Siemens SIMATIC RF310M Operating Instructions Manual page 57

Simatic sensors rfid systems mobile reader
Hide thumbs Also See for SIMATIC RF310M:
Table of Contents

Advertisement

Read StartProtocol - 2
Interface
function
2
2
2
2
2
Read/Write Data Command - 80, 81
Interface
function
80, 81
80, 81
80, 81
80, 81
80, 81
80, 81
80, 81
80, 81
80, 81
Init Tag Command - 82
Interface
function
82
82
82
82
82
82
82
SIMATIC RF310M Mobile Reader
Operating Instructions, 07/2007, J31069-D0191-U001-A1-7618
Error
Error message/display
code
1
invalid parameter
2
timeout; reader send
no start protocol;
reader not connected
3
user abort
4
BCC error
9
unknown error
Error
Error message/display
code
1
error, wrong Address
3
error, wrong length
4
error, wrong offset
40
error, error during
request
41
error, error during read
answer
42
no answer from tag/
no tag in field
43
user abort
45
error, answer not ok
255
no tag in field
Error
Error message/display
code
3
error, wrong tag type
40
error during request
41
error during read
answer
42
no answer from tag/
no tag in field
43
user abort
45
error, answer not ok
255
no tag in field
Error messages of the SIMATIC RF310M application
Meaning
Invalid parameters
No communication to the reader: Hardware missing or
defective
Abort by user
BCC error
Unknown system error
Meaning
Error in specified address
Error in specified length
Error in specified offset
Error when sending the command
Error when receiving command
No reply from tag/no tag in the field
Abort by user
Error in command response
No tag in field
Meaning
Incorrect tag type
Error when sending the command
Error when receiving command
No reply from tag/no tag in the field
Abort by user
Error in command response
No tag in field
57

Advertisement

Table of Contents
loading

Table of Contents