Yamaha NUAGE MASTER Ncs500-CT Operation Manual page 71

Hide thumbs Also See for NUAGE MASTER Ncs500-CT:
Table of Contents

Advertisement

Port page
Enables you to select the GPIO functions. You can select
up to 32 functions for input and output, respectively.
1
2
1 Target
Enables you to select either a DAW or "Custom" for the
input and output targets. You can define the details of
the "Custom" function on the Custom page.
2 Function 1
Enables you to select the GPIO functions. When a
DAW is set to Target, then "Control Room" is selected
automatically. When "Custom" is set to Target, then
you can select from the functions defined on the
Custom page.
3 Function 2
Enables you to select the GPIO functions. When a
DAW is set to Target, you can select the function from
the pop-up list displayed when you touch this item.
When the "Custom" is set to Target, then "---" is
selected automatically.
4 Device
Enables you to select the eBOX for the input and
output targets. The numbers in this column
correspond to Device 1 to Device 4 set on the Device
page.
5 Port
Enables you to select the port (GPIO terminal pin) for
the eBOX set in the Device column. Port 1 uses pin 2,
port 24 uses pin 25. Refer to the eBOX manual for
details.
6 Terminal
Defines the output port voltage and operation
performed by the input port voltage.
High
For Input, this turns on when the input port
voltage is High.
For Output, the output port voltage is set to High
when the function is on.
3
4
5
6
Low
For Input, this turns on when the input port
voltage is Low.
For Output, the output port voltage is set to Low
when the function is on.
Custom page
Enables you to define the GPIO functions. You can define
up to 16 functions.
1
1 Name
Enables you to add a name for the GPIO function to be
defined.
2 Type
Enables you to select "Momentary," "Alternate," or
"Pulse" for the input/output signal type.
Momentary
Turns the function on while the related input
port is on.
Alternate
Turns the function on or off each time the
Trigger condition is met.
Pulse
Turns the function on for a set amount of time
(approx. 250 ms) directly after the related
input port meets the Trigger condition.
3 Trigger
Enables you to define the condition for turning output
on or off. When "Type" is "Momentary," this item does
not need to be set.
When set to "Alternate," output is inverted under the
following conditions.
When set to "Pulse," output turns on under the
following conditions.
On
Output is changed when the related
input port changes from off to on.
(Alternate/Pulse)
Off
Output is changed when the related
input port changes from on to off.
(Alternate/Pulse)
Both
Output is changed when the related
input port changes from on to off or off
(Only Pulse)
to on.
Added functions in NUAGE V1.7
2
3
71