6.1 Standard Specifications

6.1.1 Model specifications

200V class
200V:Model FR-F520L-□□
Applicable motor capacity (kW)
(Note 2)
Rated capacity (kVA)
(HP)
Rated current (A)
(Note 3)
Overload capacity
(Note 4)
Voltage
Rated input AC voltage, frequency
Tolerable AC voltage fluctuation
Tolerable frequency fluctuation
Power facility capacity (kVA)
Protective structure (JEM 1030)
Cooling method
Approx. mass (kg (Ib))
400V class
400V:Model FR-F540L-□□
Applicable motor capacity
(Note 1)
(kW)
(Note 2)
(HP)
Rated
capacity
(Note 2)
(kVA)
Rated current (A)
(Note 3)
Overload capacity
(Note 4)
Voltage
Rated input AC voltage, frequency
Tolerable AC voltage fluctuation
Tolerable frequency fluctuation
Power facility capacity
(Note 5)
(kVA)
Protective structure (JEM 1030)
Cooling method
Approx. mass (kg (Ib))
Note: 1. The applicable motor capacity indicated is the maximum capacity applicable when
Mitsubishi 4-pole standard motor is used.
2. The rated output capacity (KVA) indicated is based on 220V (200V class), 440V (400V
class).
The rated output capacity (HP) indicated is based on National Electric Code for 208V and
460V.
3. The overload capacity indicated in % is the ratio of the overload current to the inverter's
rated current. For repeated duty, allow time for the inverter and motor to return to or
below the temperatures under 100% load.
4. The maximum output voltage cannot exceed the power supply voltage. The maximum
output voltage may be set as desired below the power supply voltage.
5. The power supply capacity changes with the values of the power supply side inverter
impedances (including those of the input reactor and cables).
75K
(Note 1)
75
110
100
288
120% 60 sec, 150% 0.5 sec (inverse-time characteristics)
Three phase, 200V to 230V 50/60Hz
Three phase, 200V to 230V 50/60Hz
(Note 5)
110
83
(183)
75K
75
Variable torque
75
Light Variable torque
100
Variable torque
100
Light Variable torque
110
Variable torque
110
Light Variable torque
144
Variable torque
144
Light Variable torque
Variable torque
Light Variable torque
110
Variable torque
110
Light Variable torque
41
(90.34)
(125.66)
200V
90K
90
132
125
346
170V to 253V 50/60Hz
± 5%
132
Open type (IP00)
Forced air cooling
83
(183)
90K
110K
132K
160K
90
110
132
160
90
132
160
185
150
150
200
250
150
200
250
300
137
165
198
230
137
198
230
274
180
216
260
302
180
260
302
360
120% 60 sec, 150% 0.5 sec (inverse-time characteristics)
110% 60 sec (inverse-time characteristics)
Three phase, 380V to 480V 50/60Hz
Three phase, 380V to 480V 50/60Hz
323 to 528V 50/60Hz
137
165
198
230
137
198
230
274
Open type (IP00)
Forced air cooling
57
66
66
68
(145.50)
(145.50)
(150.00)
176
SPECIFICATIONS
110K
110
165
150
432
165
85
(187)
400V
185K
220K
280K
375K
185
220
280
375
220
250
315
400
300
350
450
600
350
400
500
700
274
329
417
550
329
364
464
571
360
432
547
722
432
477
610
750
± 5%
274
329
417
550
329
364
464
571
120
120
220
235
(264.55)
(264.55)
(485.01)
(518.08)
450K
530K
450
530
-
-
700
800
-
-
660
770
-
-
866
1010
-
-
-
-
660
770
-
-
490
500
(1078)
(1100)