Setting Of Cassette Mechanism Self-Diagnosis Mode - Panasonic RX-ES22E Service Manual

Portable stereo cd system
Hide thumbs Also See for RX-ES22E:
Table of Contents

Advertisement

file:///C|/Documents and Settings/eDOK/Рабочий стол/RX-ES22/s0901020000.html
9.1.2 Setting of cassette mechanism self-
diagnosis mode
TOP PREVIOUS NEXT
1. Activate the Self Diagnosis mode with the Deck unloaded.
2. The test mode display ( [ T ] at the 1st digit shows TEST ) shall be made and detection shall be
executed to check RECINH SW, HALFSW are in OFF state.
( the tape counter display is retained )
3. Load a cassette tape ( with recording preventive tab present ) into a deck and close the cassette
holder.
4. At this instant with the cassette loaded in RECINH SW, HALF SW shall be checked and
confirmed at this stage by the software. Press FF key to proceed the self-diagnosis. The FF
operation shall stop automatically after 3 sec. If abnormal operationis detected, the tape shall stop
automatically after 1 sec. During the FF operation, the Reel Pulse shall be checked by the
software.
5. After the tape stop, the Error codes shall be displayed by toggling the STOP key.
TOP PREVIOUS NEXT
file:///C|/Documents and Settings/eDOK/Рабочий стол/RX-ES22/s0901020000.html06.11.2005 15:59:53