Editing A Path - Siemens SIMATIC S5 Manual

Interface of the programmable controller
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

S5-95U, SINEC L2
9.4

Editing a Path

Supposing you want to use a programmer connected direct to the SINEC L2 LAN to reach the
station with LAN address 2. The endpoint of the path is to be the S5-95U with the station address 2.
Figure 9-3 shows an example of how to edit the path ( Figure 9-3) with the "LAN SELECT" utility.
SINEC L2
Figure 9-3. Path to be Edited with the "BUS DIALLING" Utility
Note
The "ENDP" control processor and "CP L2" communications processor are integrated
in the S5-95U programmable controller ( section 3.1, Figure 3-2).
You must therefore show the S5-95U as consisting of "CP L2" and "ENDP" as has
been done in Figure 9-3.
EWA 4NEB 812 6112-02
Programmer Functions Over the SINEC L2 Network
PG
CP-L2
S5-95U with SINEC L2 interface
CP L2
ENDP
9-5