ALTERNATOR
Disconnect the alternator wire connectors anc;l
neutral switch wire.
Disconnect the netural switch wire from the switch.
NOTE
Do not remove the netural switch.
Oil will flow out when the switch is removed.
Remove the alternator.
CATUION
• Do not separate the pulse generator from
the stator base.
• Keep the coils in a parts rack to prevent
damaging the coil.
For alternator inspection, refer to page 15-6 and
16-4.
8-4
(1) CONNECTORS
(1) NEUTRAL SWITCH WIRE
(2) STATOR
(3) NEUTRAL SWITCH