Panasonic S-36PU1E5 Technical Data & Service Manual page 9

R410a inverter, indoor/outdoor units, 4-way cassette, ceiling, wall mounted, low shilhouette ducted, ducted
Table of Contents

Advertisement

Simultaneous (Twin) -Type
1-1. Unit Specifi cations
4-Way Cassette Type S-36PU1E5×2 / U-71PE1E8
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION
TOTAL W
O
EER/EER CLASS
TOTAL(W/W) 5/("A"~"G")
O
Pdsign
L
SEER
(W/W)
Erp
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W) 5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
3
I/D AIR
COOL
m
/min (ft
3
FLOW
HEAT
m
/min (ft
COOL
m
3
/min (ft
O/D AIR
FLOW
3
HEAT
m
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Cool (DBT)
Operation
Condition
Heat (DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
P
PIPE LENGTH RANGE
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-36PU1E5×2
CZ-KPU2
ø, Hz
1ø 50Hz
V
220
230
kW
7.1
7.1
24200
24200
A
0.19×2
0.19×2
W
20×2
20×2
-
4
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
30/28/27
47/45/44
dB-A
kW
8.0
8.0
27300
27300
A
0.17×2
0.17×2
W
20×2
20×2
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
30/28/27
47/45/44
dB-A
-
-
0.19×2/20×2 0.19×2/20×2 0.18×2/20×2
-
-
-
60×2
L/h(Pt/h)
4.2
(2.1×2)
Pa (mmAq)
-
3
/min)
14×2
3
/min)
14×2
3
/min)
3
/min)
256 (10-3/32)
840 (33-3/32)
840 (33-3/32)
298
929
929
23 (51)
29 (64)
11 (12)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
-
U-71PE1E8
CZ-P155BK1
ISO5151 / EN14825
3ø 50Hz
240
380
400
7.1
24200
0.18×2
2.80
2.70
20×2
1.760k
1.760k
1.800k
1.800k
-
900
-
3.94
3.94 / A
-
-
-
-
-
-
-
-
-
-
-
-
-
96
94
48/-
65/-
8.0
27300
0.16×2
3.10
3.00
20×2
1.960k
1.960k
2.000k
2.000k
-
4.00
4.00 / A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
96
94
-
-
50/-
67/-
-
7.0/4.150k
7.0/4.360k
-
3.10/2.0k
3.00/2.0k
-
90
(8.8)
-
(494)×2
(494)×2
60
60
R410A
2.35k
996 (39-7/32)
940 (37-1/32)
340 (13-13/32)
1136
1055
485
71 (157)
79 (175)
2 (3)
-15°C ~ 46°C
-20°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 50
(16.4 ~ 164.0)
(49.2/98.4)
50
(537.6)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-3
415
Min
Max
3.2
8.2
10900
28000
2.60
-
-
1.760k
-
-
1.800k
560
2.700k
-
-
-
3.94
5.71
3.04
-
-
-
-
94
-
-
2.8
9.0
9600
30700
2.90
-
-
1.960k
-
-
2.000k
500
2.900k
4.00
5.60
3.10
-
-
-
-
-
94
-
-
7.0/4.530k
2.90/2.0k
(2119)
(2119)
(82.9)
/
/
/
/
/
/
/
/
/
~
~
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents