Verify that all of the Access Point modules are reliably connected to the Ethernet switch by
observing that each port indicator LED on the Ethernet switch is lit.
Replace the base cover on all of the Access Point modules.
Close and lock the Cluster Management Module.
All Canopy modules connected to the Cluster Management Module must be configured to
" Sync to Received Signal ". Otherwise GPS timing pulse will not be transmitted to the
modules.

VERIFICATION

Access the web based interface for each Access Point module by opening up
address> where the < ip-address > is the address of the individual module.
Click on "GPS Status" from the menu located on the left hand side of the web page.
Verify that the Access Point module is seeing and tracking satellites. The module must be
tracking at least 4 satellites for the timing pulse to be generated.
Take a subscriber module into the area surrounding the newly installed Access Point cluster
and verify that the subscriber module registers to each of the installed Access Point modules.
The subscriber must have the same color code as the Access Point for successful registration
(assuming that there is also a clear line-of-sight).
When the subscriber module is registered, verify the following:
-
Frequency of the Access Point module registered to
-
Sector ID of the Access Point module registered to
-
Physical position of the Access Point Module registered to
If the information that is reported back does not conform to your initial deployment plan, reconfigure
the Access Point cluster to bring it into compliance.
AP_CMM2 User Manual

Figure 10: Port indicator LED on Ethernet switch

http://<ip-
Page 29 of 49