Download  Print this page

Specifications - Mitsubishi Electric JT-S1AP-W-NA Instruction Manual

Jet towel hand dryer
Hide thumbs

Advertisement

Model
Voltage
JT-S1AP-W-NA
Single-phase
120V AC
JT-S1AP-S-NA
※ The above are the fi gures when the air speed is set at "High".
■ Guide of air speed setting and drying time only model with heater
Drying times guide ※
(approx.) 9 seconds
※ Drying times are based on Mitsubishi measurements. (50mg of water per hand)
Working life of the motor/heater
The working life of the motor and heater is 7 years when used 200 times per day.
The working life may be shortened if the unit is used in a location where the power supply voltage is high or when
the operation times per user are long.
No air blows as the motor dies.
(There may odors or noise when the motor dies, but this does not indicate a malfunction.)
The air becomes cold when the heater dies. Please contact the dealer for a replacement when the heater dies.
(subject to fees)
■ Malfunction location quick reference chart
: Lit
☆ : Blinking (every 0.4 sec)
<Blinking cycle>
Blinking ... (predetermined number of blinks)
Blinks for 0.4 seconds
Light turns off for 0.4 seconds
Description
When normal
Tamper prevention
Power-supply detection abnormality
Motor abnormality 1
Motor abnormality 2
Power board temperature abnormality
Main board temperature abnormality
Microcomputer abnormality
No power/fuse opened
Be Sure to inspect older hand dryers.
User Inspection
Things
to look
for
Specifi cations
Frequency
Heater
ON
60Hz
OFF
Noise
(approx.)
62 dB
: Unlit
Light turns off
(Light turns off
for 2.4 seconds)
POWER (LED1)
2 blinks
3 blinks
4 blinks
5 blinks
6 blinks
7 blinks
• The unit does not stop blowing air.
• The air power is unstable.
• There is a burn odor.
• The leakage circuit breaker shuts dff.
• There is unusual noise or vibration during operation.
• Othere abnomalities or malfunctions.
Tokyo Building 2-7-3, Marunouchi, Chiyoda-ku, Tokyo 100-8310, Japan
Power Input (W)
Current (A)
1020
8.8
730
6.3
(The power light blinking pattern shows each error code as below chart.)
Ex: "Motor abnormality 1" blinks 3 times
0.4 sec
30-second continuous operation
Power-supply noise
Motor: lock/connector detached
Motor: brush life limit/brush abnormality
Power board: high-temperature/low-temperature
Main board: high-temperature/low-temperature
Microcomputer abnormality (main board)
Power cut-off, electric current fuse and temperature fuse opened
Stop
using
the unit
− NA - 8 −
- 8 -
Dimensions (W × D × H)
Weight
× 6
11 lb.
9
/
7
5
8
(250 × 160 × 290 mm)
(5 kg)
2.4 sec
Main cause of error
(automatic return)
(automatic return)
(automatic return)
(automatic return)
Cut off power to the unit using the circuit
breaker to avoid accidents or injury.
Make sure to contact your dealer and
consult about inspection and repair costs.
× 11
/
/
in.
7
16
16