Main unit
Main unit
9
Thread take-up lever cover attachment
2
1. Attach the thread take-up lever cover 1 to the tension base assembly 2
with the 2 screws 1.
*Key point
• Place the 2 tabs on the upper section of the thread take-up
lever cover 1 over the 2 holes 3 on the operator's side of the
tension base assembly 2, and then align the pin on the left
side of the needle bar case final assembly with the groove 4
on the inner left side of the thread take-up lever cover 1.
1
1
3
4
Torque
1
Screw, Pan (S/P washer)
1.18 — 1.57 N-m
M4X10
3 - 97