8.2
VCI Error Icon Flashes After Power
On
Most Likely Cause:
R
A problem has been detected during power on.
Recommendations:
R
Power down the VCI and verify that it has the same
problem when you power up again.
R
Connect the VCI to a PC using USB and perform the
recovery procedure.
8.3
VCI Fails to Power Up
The VCI should power up as soon as external power
is applied. If the VCI does not turn on, first check the
cable connections. Try supplying power to the VCI from
two different power sources— the vehicle DLC connec-
tor and the USB connector.
Recommendations:
R
Check that the cables are securely attached to the
VCI and the connector pins are clean.
R
If connecting to the vehicle DLC connector, try powe-
ring from the USB connector.
R
If powering from USB, try powering from the vehicle
DLC connector.
8.4
VCI Turns Off Immediately When Dis-
connected from the Vehicle
The VCI should stay on for a factory set time if power is
lost during engine cranking or after it is disconnected
from power unless you press the power button.
Recommendations:
R
Power up the VCI and verify that it has the same
problem when power is removed.
8.5
VCI Manager Software on the PC Un-
able to Communicate with the VCI
VCI Manager software must be installed on the PC, and
the VCI must be powered up before it will communicate
using USB. The VCI must also be configured for wireless
communication before it will communicate with your
wireless network. The VCI connects first using USB, if
available; if USB is not available, the VCI connects using
wireless.
Recommendations:
R
Check that the cables are securely attached to the
VCI, the VCI has completed its power up sequence,
the connector pins are clean, and the VCI Manager
software is running.
R
If connecting using USB, check that the VCI USB con-
nection is detected by Windows:
$
Connect the VCI to the PC USB port, then power
up the VCI.
Robert Bosch GmbH
Troubleshooting | MTS 6513 VCI | 13
$
From the Windows Control Panel, open the Net-
work and Dial-up Connections window.
$
Check for device name "ETAS USB Remote NDIS
Network Device". If not running, then either the
USB driver has not been loaded on the PC or the
VCI is not powered and connected to the USB.
Check all USB ports on the PC and verify that the
VCI is powered on.
R
If connecting using wireless, make sure that wireless
communication is enabled and the IP configuration
is properly set using the VCI Manager software:
$
Check that the USB cable is not plugged in. USB
connection takes precedence over wireless.
$
Check that the wireless card is properly seated in
the VCI.
$
Contact your IT department and check that your
PC is detecting the wireless access point, and the
correct security settings have been configured for
the VCI.
R
Contact your IT department for the correct VCI
settings.
R
If the VCI Manager is still not able to communicate
with the VCI, perform the Recovery Procedure.
8.6
VCI Manager ICON CHART
1.
VCI Manager will connect to VCI Via USB.
2.
VCI Manager will connect to VCI via Ethernet.
3.
VCI Manager will connect to VCI via wireless.
4.
Wireless P-to-P is not setup. Connect VCI to PC
using USB cable to complete setup.
5.
Wireless Adapter in the PC and in the VCI are in-
compatible with each other.
6.
VCI Manager is connected to the VCI.