Parameter
Reading distance
Inputs
Outputs
Table 1 Technical specifications
Value
The reading distance depends on the quality of the
cards used. The distances for Voyager devices are:
• VCU-01: 6 cm
• VCU-02: 6 cm
• VCU-03: HID 5cm, MIFARE 6 cm
• VCU-04: 6 cm
• VCU-05: HID 5 cm, iCLASS 5 cm
• VCU-06: 7 cm
• VCU-07: Sokymat 6 cm, MIFARE 6 cm
Two supervised or digital inputs:
Mode select:
• Supervised inputs for four statuses: Normal, Alarm,
Cut, and Short
• Digital inputs with two statuses: Open, Close
Current: 0~10mA for each input
Voltage: +6 VDC maximum; 0V minimum
Number: 2
Type:
Power Open Drain (Mosfet)
Load:
Inductive load admitted
When supplied directly from the reader:
Current: 30mA
Voltage: 12 VDC
When supplied from external power supply:
Current: 1.2A contiguous; 5A impulsive (0.5sec)
Voltage: 10-30 VDC