LAF 12

Error codes:

Please contact your local distributor if any of the error codes appear on the display.
Displayed code E1, flashes every 30 seconds
Fault
Effect on appliance

Technical data

Model
Power supply
Temperature range
Coolant
Amount of coolant
Dehumidifying capacity
Water tank volume
Power
Current
Weight
Dimensions
Protection class
The temperature sensor
on the coil is faulty.
Forced defrosting and lower
dehumidifying capacity.
LAF 12
220-240V/50Hz
8 to 35°C
R-134a
120 g
3,6 litres per day at RT27°C, RH 60%.
12 litres per day at RT30°C, RH 80%.
4,0 l
170 W at 20°C and 60%RH
0,8 A at 20°C and 60%RH
10,5 kg
355 x 180 x 525 mm (W x D x H)
IP21
E2, flashes every 30 seconds
The humidity sensor is faulty.
The display permanently shows 50% RH,
the appliance will continue to work in
the continuous dehumidifying mode.
23