ProForm 831.21002 User Manual
ProForm 831.21002 User Manual

ProForm 831.21002 User Manual

Hydrotherapy spa

Advertisement

Model No. 831.210020
Serial No.
The serial number can be found in the
location shown below. Write the serial
number in the space above.
Serial Number Decal
(on the frame behind the access cover)
QUESTIONS?
PLEASE CALL DIRECT TO OUR
TOLL-FREE CUSTOMER HOT
LINE. The trained technicians
on our customer hot line will
provide immediate assistance,
free of charge to you.
CUSTOMER HOT LINE:
1-800-999-3756
Mon.ÐFri., 6 a.m.Ð6 p.m. MST
CAUTION
Read all precautions and instruc-
tions in this manual before
using this equipment. Save this
manual for future reference.
Hydrotherapy Spa
USER'S MANUAL
A pH testing kit (not included) is required
for proper use and maintenance of this
product. A pH testing kit can be pur-
chased at any spa or pool supply store.
SEARS, ROEBUCK AND CO., HOFFMAN ESTATES, IL 60179
Patent Pending

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 831.21002 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ProForm 831.21002

  • Page 1 Model No. 831.210020 Serial No. The serial number can be found in the location shown below. Write the serial number in the space above. Serial Number Decal (on the frame behind the access cover) QUESTIONS? PLEASE CALL DIRECT TO OUR TOLL-FREE CUSTOMER HOT LINE.
  • Page 2: Table Of Contents

    This warranty gives you specific legal rights. You may also have other rights which vary from state to state. ICON HEALTH & FITNESS, INC., 1500 S. 1000 W., LOGAN, UT 84321-9813 PROFORM ¨ is a registered trademark of ICON Health & Fitness, Inc. The RESTORATION 2.0 is sold by SEARS.
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF DROWNING, ELECTRIC SHOCK, OR SERIOUS INJURY, READ THE FOLLOWING IMPORTANT PRECAUTIONS BEFORE USING THE RESTORATION 2.0. READ AND FOLLOW ALL INSTRUCTIONS 1. It is the responsibility of the owner to ensure that all users of the RESTORATION 2.0 are adequately informed of all precautions.
  • Page 4 20. Do not use an extension cord with the RESTORATION 2.0. This could damage the motor and will void the warranty. 21. DANGERÑIf you will be using the RESTORA- TION 2.0 outside, do not bury the power cord; you should also keep the power cord away from lawn mowers, hedge trimmers, and other similar equipment.
  • Page 5: Save These Instructions

    34. WARNINGÑTo reduce the risk of injury or drowning: Consult your physician about pos- sible side-effects of any medications you may be taking before using the RESTORA- TION 2.0. Heat from the water, in conjunction with some medications may cause drowsi- ness and increase the risk of drowning.
  • Page 6: Before You Begin

    BEFORE YOU BEGIN Thank you for selecting the innovative PROFORM RESTORATION 2.0 Massage Spa. The RESTORA- TION 2.0 offers the features and quality of a traditional hot tub at an affordable price. Best of all, the RESTORATION 2.0 provides the benefits of hydrother- apy in the comfort of your own home.
  • Page 7: Choosing A Location For The Restoration 2.0

    CHOOSING A LOCATION FOR THE RESTORATION 2.0 There are many factors to consider when choosing a location to set up the RESTORATION 2.0. These factors vary depending on whether you use the RESTORATION 2.0 inside or outside. We have listed several factors you may wish to consider as you decide where you want to use the RESTORATION 2.0.
  • Page 8: Set-Up And Assembly

    SET-UP AND ASSEMBLY Before beginning assembly, carefully read the following information and instructions: ¥ Place all parts in a cleared area and remove the packing materials from the spa shell; do not dis- pose of the packing materials until assembly is completed.
  • Page 9 4. Insert a Support Ball (8) into each mesh pocket on the underside of the Spa Cover (12). See inset drawing A. Insert the inflation tube into the hole in one of the Support Balls (8). Inflate the Support Ball. See inset drawing B.
  • Page 10: Using The Restoration 2.0

    USING THE RESTORATION 2.0 The RESTORATION 2.0 is designed to seat two adults. The six thera-jets can be regulated to provide a relaxing massage to sooth away stress, and the strength of the water massage can be adjusted by the air control.
  • Page 11: Using The Console

    USING THE CONSOLE Refer to the console diagram above. The function of each console control is explained below: Temperature: Controls the temperature of the water. The water heats at about 2.0¡F an hour with the cover on. The thermostat can be set to heat the water from 70¡F to 104¡F.
  • Page 12: Posting The Warning Sign

    USING THE INSULATION BLANKET The insulation blanket works with the spa cover to trap the heat and help the water to heat faster. To use the blanket, simply lay it on the surface of the water after you have filled the spa and treated the water. You should always replace the blanket and cover once you get out of the spa.
  • Page 13: Maintenance

    MAINTENANCE The RESTORATION 2.0 is designed to provide you with years of enjoyment. Please follow the guidelines below to properly maintain your spa. MAINTENANCE SCHEDULE DAILY ¥ Check the water level and refill the spa to the level shown on page 8, step 1. ¥...
  • Page 14: Water Chemistry

    WATER CHEMISTRY The RESTORATION 2.0 comes with a starter chemi- cal pack for maintaining the water in the spa. (See TESTING AND TREATING THE WATER on page 10.) Additional chemicals can be purchased at a pool and spa supply store. CAUTION: The chemicals used to maintain the pH balance of the water and to sanitize the water can be dangerous.
  • Page 15: Draining The Pump

    2. Unplug the power cord. 3. Remove the access cover from the back of the spa unit. 4. Remove the drainage hose from the clip and attach a garden hose to the valve on the drainage hose. Drain Hose 5. Open the valve by turning the knob counterclock- wise.
  • Page 16: Trouble-Shooting

    TROUBLE - SHOOTING Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-800-999-3756, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time. 1.
  • Page 17 8. SYMPTOM: THE WATER PULSATES OR THERE IS MINIMUM WATER FLOW a. Adjust the water level. This usually occurs only when the water level is low. Add water until the thera-jets are covered (see step 1 on page 8). 9. SYMPTOM: THE WATER IS NOT BEING CLEANED BY THE FILTER a.
  • Page 18: Part List

    PART LISTÑModel No. 831.210020 Key No. Qty. Description Buckle Screw Buckle Motor Screw Washer Rubber Insulator Heat Sensor Console Support Ball Power Cord/Supply Rubber Damper Pump Motor Insulation Blanket Spa Cover Drowning Warning Decal Spa Unit Sun Warning Decal Filter Housing Housing Ring Cover Screws Filter Cover...
  • Page 19: Exploded Drawing

    EXPLODED DRAWINGÑModel No. 831.210020 R0198A...
  • Page 20: Ordering Replacement Parts

    1. The MODEL NUMBER of the product (831.210020). 2. The NAME of the product (RESTORATION 2.0 by PROFORM ¨ 3. The SERIAL NUMBER of the product (see the front cover of this manual).

This manual is also suitable for:

831.210020Restoration 2.0

Table of Contents