To connect the power cord from the server to an interruptive power supply (UPS), use service
outlets on the rear of the UPS.
The UPS service outlets are categorized into two groups: SWITCH OUT and UN-SWITCH
OUT. (They may be called "OUTPUT1" and "OUTPUT2".)
To control power supply with an application (NEC ESMPRO/UPSController) that controls the
UPS, connect the power cord to an SWITCH OUT outlet.
For constant power supply, connect the power cord to a UN-SWITCH OUT outlet. (Connect
the modem that is in service for 24 hours to this outlet.)
<Example>
When the power cord from the server to a UPS, change the BIOS setup of the server to link
with power supply from the UPS.
Change a parameter for "AC-Link" under the Server menu of the BIOS SETUP utility. See
Chapter 4 for details.
56 Setting Up Your Storage Server
2
OUTPUT
(UNSWITCH OUT)
UN-SWITCH OUT
(OUTPUT 2)
OUTPUT(SWITCH OUT)
AC100V 50/50HZ
SWITCH OUT
(OUTPUT 1)