GE C30 Instruction Manual page 358

Controller system ur series
Hide thumbs Also See for C30:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
value
GOOSE dataset item
178
GGIO3.ST.UIntIn7.q
179
GGIO3.ST.UIntIn7.stVal
180
GGIO3.ST.UIntIn8.q
181
GGIO3.ST.UIntIn8.stVal
182
GGIO3.ST.UIntIn9.q
183
GGIO3.ST.UIntIn9.stVal
B
184
GGIO3.ST.UIntIn10.q
185
GGIO3.ST.UIntIn10.stVal
186
GGIO3.ST.UIntIn11.q
187
GGIO3.ST.UIntIn11.stVal
188
GGIO3.ST.UIntIn12.q
189
GGIO3.ST.UIntIn12.stVal
190
GGIO3.ST.UIntIn13.q
191
GGIO3.ST.UIntIn13.stVal
192
GGIO3.ST.UIntIn14.q
193
GGIO3.ST.UIntIn14.stVal
194
GGIO3.ST.UIntIn15.q
195
GGIO3.ST.UIntIn15.stVal
196
GGIO3.ST.UIntIn16.q
197
GGIO3.ST.UIntIn16.stVal
F237
ENUMERATION: REAL TIME CLOCK MONTH
value
month
0
January
1
February
2
March
3
April
4
May
5
June
6
July
7
August
8
September
9
October
10
November
11
December
F238
ENUMERATION: REAL TIME CLOCK DAY
value
day
0
Sunday
1
Monday
2
Tuesday
3
Wednesday
4
Thursday
5
Friday
6
Saturday
B-60
F239
ENUMERATION: REAL TIME CLOCK DAYLIGHT SAVINGS
TIME START DAY INSTANCE
value
instance
0
First
1
Second
2
Third
3
Fourth
4
Last
F254
ENUMERATION: TEST MODE FUNCTION
Value
Function
0
Disabled
1
Isolated
2
Forcible
F260
ENUMERATION: DATA LOGGER MODE
0 = Continuous, 1 = Trigger
F300
UR_UINT16: FLEXLOGIC™ BASE TYPE (6-bit type)
The FlexLogic™ BASE type is 6 bits and is combined with a 9 bit
descriptor and 1 bit for protection element to form a 16 bit value.
The combined bits are of the form: PTTTTTTDDDDDDDDD,
where P bit if set, indicates that the FlexLogic™ type is associated
with a protection element state and T represents bits for the BASE
type, and D represents bits for the descriptor.
The values in square brackets indicate the base type with P prefix
[PTTTTTT] and the values in round brackets indicate the descrip-
tor range.
[0] Off(0) – this is boolean FALSE value
[0] On (1) – this is boolean TRUE value
[2] CONTACT INPUTS (1 to 96)
[3] CONTACT INPUTS OFF (1 to 96)
[4] VIRTUAL INPUTS (1 to 64)
[6] VIRTUAL OUTPUTS (1 to 96)
[10] CONTACT OUTPUTS VOLTAGE DETECTED (1 to 64)
[11] CONTACT OUTPUTS VOLTAGE OFF DETECTED (1 to 64)
[12] CONTACT OUTPUTS CURRENT DETECTED (1 to 64)
[13] CONTACT OUTPUTS CURRENT OFF DETECTED (1 to 64)
[14] REMOTE INPUTS (1 to 32)
[28] INSERT (via keypad only)
[32] END
[34] NOT (1 INPUT)
[36] 2 INPUT XOR (0)
[38] LATCH SET/RESET (2 inputs)
[40] OR (2 to 16 inputs)
[42] AND (2 to 16 inputs)
[44] NOR (2 to 16 inputs)
[46] NAND (2 to 16 inputs)
[48] TIMER (1 to 32)
[50] ASSIGN VIRTUAL OUTPUT (1 to 96)
[52] SELF-TEST ERROR (see F141 for range)
C30 Controller System
APPENDIX B
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents