Chapter 3
Storage System Monitoring
3.3

Displaying Status via ETERNUS CLI

Status of the ETERNUS AF is monitored periodically, and the result is displayed as a general status icon with
character strings.
Table 3.1 General Status of ETERNUS Web GUI
Status
For details, refer to "Configuration Guide (Web GUI)".
3.3
Displaying Status via ETERNUS CLI
The status of the ETERNUS AF and the usage status of RAID groups, TPPs, and SDPs can be checked by send-
ing the status display command via ETERNUS CLI.
CLI> show status
Summary Status [Normal]
CLI> show status
Summary Status [Error]
CLI> show status
Summary Status [Warning]
The general status of the ETERNUS AF indicates whether an error status component or a warning status com-
ponent exists in the storage system.
Table 3.2 General Status of ETERNUS CLI
Status
Empty
Normal
Pinned Data
Unused
Warning
Maintenance
Error
Loop Down
Not Ready
Subsystem Down
Change Assigned CM
(green)
(red)
(red)
(orange)
(yellow)
Description
An undefined or uninstalled component exists in the ETERNUS AF.
The ETERNUS AF is in a normal state.
Pinned data exists in the ETERNUS AF.
An undefined component is installed in the ETERNUS AF.
The ETERNUS AF contains a component that requires preventive maintenance.
The ETERNUS AF is under maintenance.
An error has occurred in a component that is installed in the ETERNUS AF.
The ETERNUS AF is in the BackEnd Down state.
An abnormality is detected and access from the host cannot be received.
The ETERNUS AF cannot be used.
CM hot expansion recovery is required.
FUJITSU Storage ETERNUS AF650 S2, ETERNUS AF650 All-Flash Arrays Operation Guide (Basic)
Copyright 2017 FUJITSU LIMITED
Description
The ETERNUS AF is in a normal state.
An abnormality is detected at a power-off, and I/O access from the server
cannot be received.
The ETERNUS AF is in error state.
The ETERNUS AF is under maintenance.
The ETERNUS AF is in warning state.