FAULT CODES

The battery condition meter will flash fault codes when the controller system
detects an abnormal condition in the electrical system. All of the battery con-
dition meter LEDs will flash a number of times quickly, then pause, then flash
again. The battery condition meter will continue to flash the fault codes until
the problem is fixed. The table below identifies the individual fault codes. If
any of these fault codes persist, contact your authorized Pride Provider.
Fault
Codes
1 Flash
The batteries need charging.
There is a bad connection to
the batteries.
2 Flashes
There is a bad connection on
the left motor.
3 Flashes
The left motor has a short to
the battery connection.
There is a bad connection on
4 Flashes
the right motor.
The right motor has a short to a
5 Flashes
battery connection.
Scroll Left
The charge inhibit has been
activated.
to Right
There is a joystick fault.
7 Flashes
8 Flashes
There is a control system fault.
The park brakes have a bad
9 Flashes
connection.
An excessive voltage has been
10 Flashes
applied to the control system.
GC Controller
Probable Causes
www.pridemobility.com
Basic Operation Instructions
Possible Solutions
Check the battery connections. If the
battery connections are good, then try
charging the batteries.
Check the left motor connections and
wiring harnesses.
Contact your authorized Pride Pro-
vider.
Check the right motor connections
and wiring harnesses.
Contact your authorized Pride Pro-
vider.
Make sure that the battery charger is
not connected to the power base.
Make sure the joystick is in the cen-
ter position and then power off and
on again.
Check power module and joystick
module connections and wiring.
Check the left and right motor con-
nections and wiring.
Check the battery connections.

Advertisement