Wiring And Tubing; Typical Fixed Installation Topologies - Honeywell SPM Flex User Manual

Single point monitor gas detector
Hide thumbs Also See for SPM Flex:
Table of Contents

Advertisement

Wiring and tubing

Typical fixed installation topologies

The SPM Flex gas detector has flexible installation options to allow the user to
select the one most suitable for a specific application� The detector is supplied
with weather-sealed connectors for both power and Ethernet, and with a third
port sealed� A third connector for communications is installed (for relays or
4-20 mA), or any of the ports can be replaced with appropriate connections in
accordance with local codes (allowing the user to wire directly to the terminal
block)� Install the detector near a dedicated circuit breaker�
CAUTION
!
The safety of any system incorporating the SPM Flex gas detector is the
responsibility of the assembler of the system�
Position a permanently-installed SPM Flex gas detector so that it does not
interfere with access to the dedicated circuit breaker�
Electrical connection is made via conduit directly to ports or via the connector
(see Figure 1 on page 10)� The terminals used are suitable for conductors of 24
to 14 AWG (0�5 to 1�8mm Dia�)� The use of 16 AWG (1�5 mm dia�) conductors is
recommended�
CAUTION
!
Use the supplied power adaptor/connector only� (The adaptor is rated for
indoor use only�)
SPM Flex Gas Detector
19