What the end users responsibility is, including daily, weekly, quarterly & annual checks 4. PANEL INDICATIONS & CONTROLS …………………………..………………………….. A list of indicator LEDs & Control Buttons on the Premier SX Fire Alarm Panel GENERAL CONTROLS ACCESSED CONTROLS SUMMARY OF LED COMBINATIONS AND THEIR MEANING CHECKING THE PANELS INDICATION LEDS 5.
(Ask the installation company for recommendations). The system needs a thorough maintenance check annually at the very minimum. If any part of this Fire Alarm Control Panel becomes damaged, contact the company responsible for system maintenance to arrange repair / replacement.
Ensure any changes to the system are recorded with updated drawings, operating instructions etc (47.2.i) 10. Ensure that there are spare parts (especially Call point elements) held on site (47.2.j.1&2) With the Premier SX Range of Fire Alarm Panels, we recommend the following tests are carried out: - Daily Inspection •...
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK 4. PANEL INDICATIONS & CONTROLS FIRE / ZONES POWER SUPPLY FLT ZONAL FAULT / DISABLEMENT / TEST GEN-FIRE GEN-FAULT SYSTEM FLT GEN-S/C STOP-START SILENCE RESET FLT TONE Two levels of control are available to the User(s) of this Fire Alarm Panel.
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK 4.3 SUMMARY OF LED COMBINATIONS AND THEIR MEANING Use the table below to determine the condition of the panel. LEDs LIT LED CONDITION POWER CONSTANT GREEN GEN FLT CONSTANT YELLOW ONLY GEN FLT &...
SCROLL / / LED TEST FLT TONE When the Premier SX Fire Alarm Panel is set into alarm by a Detector or Manual Call Point located in a zone that is not already in alarm it will: - • Light the General Fire LED and appropriate Zone Fire LED(s) on the front of its enclosure •...
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK 6. THE FAULT CONDITION 6.1 DIFFERENT TYPES OF FAULT The fire alarm monitors itself, and any equipment connected to it, for any faults that can occur. If a fault occurs, the Panel responds by activating its Internal buzzer and lighting the General Fault light and any other Fault light(s) relevant to the particular fault.
(Usually by contacting the service engineer) On the Premier SX panel, the fault indications (except system fault) are non latching. That is, when the fault has been cleared, the fault indication will turn off. When all faults have been cleared, the panel will return to its quiescent (normal) condition.
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK 7. DISABLEMENTS 7.1 REASONS FOR DISABLING CERTAIN PARTS OF A FIRE ALARM SYSTEM. Certain parts of this Fire Alarm Panel can be temporarily disabled (i.e. switched off) to suit prevailing conditions. For example, if there is a risk of a False Alarm in a zone, for example, from vehicle exhaust smoke in a loading bay, it is possible for the user to disable that zone during the risk period and then enable it again afterwards.
8.2 SOUNDER DELAY SETTING On the Premier SX panel, the sounder delay is global. That is, all zones will be delayed by the same amount. The delay can be set between 1 minute and 9 minutes, by turning the rotary dial to the relevant position, or the delay can be left off (sounders activate immediately), by leaving the dial at the 0 position.
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK 9. SYSTEM DESCRIPTION FIRE ALARM SYSTEM SUMMARY: FIRE ZONE INFORMATION ZONE ZONE DESCRIPTION NUMBER A brief description of all the rooms and areas contained in each zone Sounder SOUNDER CIRCUIT DESCRIPTION...
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK 10. FIRE ALARM LOG BOOK It is recommended that this LOG BOOK section of the Manual be maintained by the responsible person(s) on site, who should ensure every event is properly recorded (including fire alarm conditions, failures, tests, temporary disconnections, disablements, enablements, dates of installing engineers’...
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK MAINTENANCE WORK DATE TIME ZONE / LOCATION REASON FOR WORK WORK CARRIED OUT ADDITIONAL WORK REQUIRED SIGNED PAGE 14 Approved Document No: GLT.MAN-102 Issue: 1.3 Authorised: GH Date: 9/6/2004...
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FALSE ALARMS DATE TIME ZONE / CAUSE (IF KNOWN) LOCATION OR ACTIVITIES IN ALARM AREA Approved Document No: GLT.MAN-102 Issue: 1.3 Authorised: GH MAINTENANCE MAINTENANCE VISIT NEEDED FINDINGS (YES/NO) Date: 9/6/2004...
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK ALL EVENTS OTHER THAN MAINTENANCE WORK OR FALSE ALARMS DATE TIME ZONE / LOCATION Approved Document No: GLT.MAN-102 Issue: 1.3 Authorised: GH DETAILS OF EVENT (INCLUDING CAUSE IF KNOWN) Date: 9/6/2004...
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK 11 COMMISSIONING THE SYSTEM, INCLUDING P.S.E. • The commissioning of this fire alarm system should be performed by a qualified commissioning engineer, who has an understanding of sections 2,3,& 4 of BS5839 pt 1:2002 (i.e. Design considerations, Limitations of false alarms, Installation recommendations) •...
Page 18
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Certificate of Design for the Premier SX Fire Alarm System installed at: Address: I/we being the competent person(s) responsible (as indicated by my/our signatures below) for the design of the fire alarm system, particulars of which are set out below, CERTIFY that the said design...
Page 19
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Measures incorporated to limit false alarms. Account has to be taken of the guidance contained in section 3 of BS 5839-1: 2002 and, more specifically (tick as appropriate): The System is manual. Type & siting of manual call points takes account of the guidelines...
Page 20
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Certificate of Installation for the Premier SX Fire Alarm System installed at: Address: I/we being the competent person(s) responsible (as indicated by my/our signatures below) for the installation of the fire alarm system, particulars of which are set out below, CERTIFY that the said...
Page 21
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Certificate of COMMISSIONING for the Premier SX Fire Alarm System installed at: Address: I/we being the competent person(s) responsible (as indicated by my/our signatures below) for the commissioning of the fire alarm system, particulars of which are set out below, CERTIFY that the said...
Page 22
PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Certificate of Acceptance for the Premier SX Fire Alarm System installed at: Address: I/we being the competent person(s) responsible (as indicated by my/our signatures below) for the acceptance of the fire alarm system, particulars of which are set out below, ACCEPT the system...