7.4.5
Sleeping Cell Detection
This is a function that allows the APC to detect the statuses of APs that are not performing
basic functions and transmit an alarm/warning.
Configuration using CLI
1) Enable/Disable: Configure whether the silent alarm detection function will be
performed.
(Enable: function performing, Disable: function not performing)
WEC8500/configure/rrm# sleep-cell-detect
WEC8500/configure/rrm/sleep-cell-detect# enable
2) APC Threshold: Minimum number of connected users throughout the whole APC for
sleeping cell detection.
If the total number of STA associations is equal to or smaller than the APC threshold,
the day is judged as a holiday and consequently the sleeping cell detection is not
performed.
WEC8500/configure/rrm/sleep-cell-detect# apc-threshold
3) AP Threshold: Minimum number of users connected to an AP for sleeping cell detection.
If the number of STA associations of an AP is equal to or smaller than the AP
threshold, a silent alarm occurs.
WEC8500/configure/rrm/sleep-cell-detect# ap-threshold
4) PERIOD_1ST: Start and end times of sleeping cell detection for Specific Period 1.
(For a full day, set the start and end times as the same time.)
WEC8500/configure/rrm/sleep-cell-detect# period_1st
5) PERIOD_2ND: Start and end times of sleeping cell detection start for Specific Period 2.
(For a full day, set the start and end times as the same time.)
WEC8500/configure/rrm/sleep-cell-detect# period_2nd
6) PERIOD_ALL: Start and end times of sleeping cell detection for periods other than
Specific Periods 1 and 2.