WEC8050 / WEC8500 Operation Manual
4.2.6
Outdoor AP Configuration
The APC system provides outdoor AP connection diagnostic functions for outdoor APs.
The AP connection diagnostics function checks ping status of outdoor APs and displays the
results on the operator's monitor.
Procedure of using the outdoor AP connection diagnostics function is as follows:
1) The operator creates/deletes outdoor APWEC using CLI.
2) The APC system periodically pings the outdoor AP to check the network connection of
the AP and stores the results.
3) The operator uses the WEC, WEM or CLI to determine network connection status of
the outdoor AP.
Concerning outdoor AP count:
1) Outdoor APs are not included in the AP count of the APC license.
2) Outdoor APs are not included in the ordinary AP count.
3) The maximum up-ported outdoor AP count is 300 for the WEC8500 model and 75 for
the WEC8050 model.
4) The APC system can retrieve the total/up/down outdoor AP count using the WEC or
CLI.
4.2.6.1
Outdoor AP Addition/Removal
The APC system allows creation/deletion of outdoor AP information using the WEC or
CLI.
Configuration using CLI
1) Go to the configure mode of the CLI.
WEC8500# configure terminal
WEC8500/configure#
2) Create or delete an AP. Use the 'no' parameter in front of the command to delete an
outdoor AP.
outdoor-ap [PROFILE_NAME] [MAC_ADDRESS] [IP_ADDRESS]
no outdoor-ap [PROFILE_NAME]
3) Create or delete an outdoor AP. Use the 'no' parameter in front of the command to
delete an outdoor AP.
4) Use the 'show ap summary' command to check the outdoor AP information.