Repair instructions
Replacing a worn recoil spring
!
WARNING!
Make sure the recoil spring does
not fly out and cause injury. Wear
eye protection.
1
Remove the bolt from the centre of the pulley and
lift off the pulley and spring.
2
Remove the broken recoil spring.
3
Fit a new recoil spring, with the retaining wire still
in place. Do not remove the wire until the spring is
in position. If the spring comes loose when you put
it in place wind it up from the outside working
inwards.
Lubricate the recoil spring with light oil.
4
Fit the bolt through the centre of the pulley and
tighten to a torque of 2–3 Nm.
Tension the recoil spring (see page 21).
22
– English
Starter assembly – refitting
1
Position the starter assembly on the crankcase and
tighten the bolts to a torque of 2.5–3.5 Nm.
Ignition module – testing
If there is a fault in the ignition system the ignition
module must be tested before the ignition system
is removed.
Test the ignition module as follows:
• Connect a test spark plug 502 71 13-01 to the
ignition lead and clip the test spark plug onto the
cylinder.
• Turn the engine over using the starter cord.
• If the test spark plug produces a spark the
ignition module is OK.