7.1.1 Utility—Diagnosis—Card Diagnosis
Note
•
Cards installed in KX-NS1000 PBXs and legacy gateway KX-NCP PBXs cannot be tested using this
utility.
•
The cards to be used for testing must be installed in the same legacy gateway PBX.
The tests that are performed are as follows:
Line current OFF (Ext->CO)
Line current ON (Ext->CO)
Off hook detection (CO->Ext)
DTMF detection (CO->Ext)
DP detection (CO->Ext)
BELL detection (Ext->CO)
Speech path (Ext->CO)
Speech path (CO->Ext)
To perform a pair port test
1.
Click on the Status cell of the extension card to be tested, and set it to "OUS".
2.
Click Test.
A new window will be displayed.
3.
Select the Pair Port Test option. A new window will be displayed.
4.
In Extension Line, in the Site-Shelf-Slot No. drop-down list, select the extension card to test. Each card
will be preceded by a 3-digit number, following the pattern "XYZ":
•
X: Site number (1–16)
•
Y: Shelf number (2–3 [Corresponding to Legacy Gateway 1 or 2])
•
Z: Slot number (1–11)
5.
From the Port No. drop-down list in Extension Line, select the port number of the extension to test.
6.
In CO Line, in the Site-Shelf-Slot No. drop-down list, select the trunk card to test. Each card will be
preceded by a 3-digit number, following the pattern "XYZ" as described in step 4.
7.
From the Port No. drop-down list in CO Line, select the port number of the trunk to test.
8.
Click Test.
The error report will be displayed.
9.
Select an option:
•
Click Capture if you want to save the displayed information.
1.
Specify the save destination and file name.
2.
Click Save.
•
Click Cancel to return to the Diagnosis screen.
114
PC Programming Manual
Line current from extension to trunk turns off.
Line current from extension to trunk turns on.
Off-hook generation/detection from trunk to extension
DTMF generation/detection from trunk to extension
DP generation/detection from trunk to extension
BELL generation/detection from extension to trunk
Speech path from extension to trunk
Speech path from trunk to extension