Voltage Detectors Check - Casio PA-2400U Service Manual And Parts List

Handled personal computer
Table of Contents

Advertisement

Voltage Detectors Check

Check the following detectors;
VDET1:
Low battery message detector for alkaline batteries.(2.1V)
VDET2:
Foced power off detector for alkaline batteries.(1.6V)
VDET1R:
Low battery message detector for rechargeable battery.(3.6 V )
VDET2R:
Foced power off detector for rechargeable battery.(3.0 V)
VDETS:
Low battery message detector for back-up battery.(2.7 V )
Step
Operation
Vb = 2.6 ± 0.02 V
Setting
Tap "21.LB" on the dis-
play.
VDET1
Put power supply voltage
down by degrees.
Put power supply voltage
VDET2
down by degrees.
Display (Wiring)
Alkaline battery terminal
-
V
PA-2400U
+
Vb
AC adapter
Charger
<< LB >>
VDET1
OFF
VDET2
OFF
VDET1R
OFF
VDET2R
OFF
VDETS
OFF
Li
AM3
[ Push Notification Button ]
VDET1
ON
VDET2
OFF
VDET1
ON
VDET2
ON
— 61 —
Note
Connect the items as
shown.
Measure the voltage that
VDET1 becomes ON.
=
VDET1
2.1 V
Measure the voltage that
VDET2 becomes ON.
=
VDET2
1.6 V