Menu Function 4 - Standby; Menu Function 5 - Time Until Standby - Sitec Delta Operator's Manual

Table of Contents

Advertisement

...keeping you secure

3.5 Menu function 4 - Standby

This menu function can be used to cancel the standby function.
This function applies to all the connections to the individual extensions.
0:
No standby function
1:
The standby function can only be cancelled using the on/off button.
2:
The standby function can either be cancelled using the on/off button or if
someone is speaking externally.
In addition to speech recognition, a proximity switch connected to the
central control signals that a customer is in range.
3:
The standby is either cancelled using the on/off button or if someone is
speaking externally.

3.6 Menu function 5 - Time until Standby

This menu function is used to activate the standby function.
This function applies equally to all connections to the individual extensions.
0:
Standby function is only activated using the on/off button
1:
The intercom automatically switches into standby mode if noone has
spoken on either side for more than 30 seconds.
2:
The intercom automatically switches into standby mode if noone has
spoken on either side for more than 60 seconds.
3:
The intercom automatically switches into standby mode if noone has
spoken on either side for more than 120 seconds.
4:
The intercom automatically switches into standby mode if noone has
spoken on either side for more than 300 seconds.