Property
Ambient conditions for transport in the transport packaging
Climatic ambient conditions
Mechanical ambient condi‐
tions
Protection against chemical
substances
Biological environmental
conditions
Ambient conditions for long-term storage in the product packaging
Climatic ambient conditions
Protection against chemical
substances
Biological environmental
conditions
Ambient conditions in operation
Installation altitude
Climatic ambient conditions
1)
Mechanical ambient condi‐
tions
Protection against chemical
substances
Biological environmental
conditions
Pollution
Cooling
Cooling air
Increased ruggedness regarding temperature range and relative humidity; therefore better than Class 3K3 to EN 60721-3-3
1)
Observe the permissible ambient temperatures for the Control Unit and possibly the operator panel (IOP or BOP-2).
2)
62
Version
‑ 40 °C ... + 70 °C, according to Class 2K4 to EN 60721‑3‑2
maximum humidity 95 % at 40 °C
FSA ... FSC: Shock and vibration permissible according to 1M2 to EN 60721‑3‑2
FSD ... FSF: Shock and vibration permissible according to 2M3 to EN 60721‑3‑2
Protected according to Class 2C2 to EN 60721‑3‑2
Suitable according to Class 2B1 to EN 60721‑3‑2
‑ 25 °C ... + 55 °C, according to Class 1K3 to EN 60721‑3‑1
Protected according to Class 1C2 to EN 60721‑3‑1
Suitable according to Class 1B1 according to EN 60721‑3‑1
Up to 1000 m above sea level without derating,
> 1000 m
Restrictions for special ambient conditions (Page 69)
● Temperature range without derating
LO base load power:
HO base load power:
For higher temperatures.
Restrictions for special ambient conditions (Page 69)
● Relative humidity: 5 ... 95%, condensation not permitted
● Oil mist, salt mist, ice formation, condensation, dripping water, spraying water, splashing
water and water jets are not permitted
FSA ... FSF: Vibration levels permissible according to Class 3M1 to EN 60721-3-3
FSA ... FSC: Shock, permissible according to Class 3M2 to EN 60721-3-3
FSD ... FSF: Shock permissible according to Class 3M1 to EN 60721-3-3
protected according to 3C2 acc. to EN 60721‑3‑3
suitable according to 3B1 acc. to EN 60721‑3‑3
Suitable for environments with degree of pollution 2 according to EN 61800-5-1
Forced air cooling AF, according to EN 60146
clean and dry air
2)
0 °C...40 °C
0 °C...40 °C
Power Module PM230, IP20 / Push-through technology (PT)