Xstatus Systemunit Hardware Monitoring Fan [N] Status; Xstatus Systemunit Hardware Temperature; Xstatus Systemunit Notifications Notification [N] Text; Xstatus Systemunit Notifications Notification [N] Type - Cisco TelePresence DX70 Reference Manual

Application programming interface
Hide thumbs Also See for TelePresence DX70:
Table of Contents

Advertisement

Cisco TelePresence DX70 and DX80
Introduction

xStatus SystemUnit Hardware Monitoring Fan [n] Status

The feedback shows the speed (rpm) for the specified fan.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus SystemUnit Hardware Monitoring Fan 1 Status
*s SystemUnit Hardware Monitoring Fan 1 Status: "locked on 1096 rpm"
** end

xStatus SystemUnit Hardware Temperature

Shows the current maximum temperature (degree Celsius) measured in the codec/system.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus SystemUnit Hardware Temperature
*s SystemUnit Hardware Temperature: "64.0"
** end

xStatus SystemUnit Notifications Notification [n] Text

Lists text related to important system notifications. Notifications are issued e.g. when a system
was rebooted because of a software upgrade, or when a factory reset has been performed.
All the notifications can be removed from the list by issuing the xCommand SystemUnit
Notifications RemoveAll command.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus SystemUnit Notifications Notification 1 Text
*s SystemUnit Notifications Notification 1 Text: "OK"
** end
D15363.05 Cisco TelePresence DX70 and DX80 API Reference Guide CE9.2, NOVEMBER 2017.
About the API
xConfiguration
xCommand

xStatus SystemUnit Notifications Notification [n] Type

Lists the system notification types. Notifications are issued e.g. when a system is rebooted
because of a software upgrade, or when a factory reset is performed.
FactoryResetOK: This value is returned after a successful factory reset.
FactoryResetFailed: This value is returned after a failed factory reset attempt.
SoftwareUpgradeOK: This value is returned after a successful software upgrade.
SoftwareUpgradeFailed: This value is returned after a failed software upgrade attempt.
RebootRequired: This value is returned when a reboot is required.
Other: This value is returned for any other notifications.
All the notifications can be removed from the list by issuing the xCommand SystemUnit
Notifications RemoveAll command.
Requires user role: ADMIN, USER
Value space of the result returned:
FactoryResetOK, FactoryResetFailed, SoftwareUpgradeOK, SoftwareUpgradeFailed,
RebootRequired, Other
Example:
xStatus SystemUnit Notifications Notification 1 Type
*s SystemUnit Notifications Notification 1 Type: SoftwareUpgradeOK
** end

xStatus SystemUnit ProductId

Shows the product identity.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus SystemUnit ProductId
*s SystemUnit ProductId: "Cisco TelePresence Codec SX80"
** end
184
API Reference Guide
xStatus
xStatus
Appendices
Copyright © 2017 Cisco Systems, Inc. All rights reserved.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Telepresence dx80

Table of Contents