Fetco CBS-1131-XV+ User's Manual & Operating Manual

Fetco CBS-1131-XV+ User's Manual & Operating Manual

Cbs-1130 extractor v+

Advertisement

FETCO COFFEE BREWER: CBS-1130 EXTRACTOR
CBS-1131-XV+

TABLE OF CONTENTS

Specifications and Requirements .................................. 2
Rough-In Drawings ........................................................ 2
Electrical and Output Specifications .............................. 3
Starting The Brew .......................................................... 4
Enter Programming ........................................................ 4
Exit Programming & Save .............................................. 4
PROGRAMMING MENU LAYOUT ................................ 5
A PROGRAM ................................................................. 6
B GENERAL................................................................... 7
C INPUTS ...................................................................... 8
D OUTPUTS .................................................................. 8
E OTHER ....................................................................... 8
F SAVE & EXIT .............................................................. 9
CONTACT INFORMATION
FETCO®
FOOD EQUIPMENT TECHNOLOGIES COMPANY
600 ROSE ROAD
LAKE ZURICH • IL • 60047-0429 • USA
INTERNET: www.fetco.com
©2017 FOOD EQUIPMENT TECHNOLOGIES COMPANY
USER'S GUIDE & OPERATOR INSTRUCTIONS
 
 
 
 
 
 
 
 
 
 
 
 
 
Error Codes..................................................................... 9
Operator Training .......................................................... 10
Installation Guide .......................................................... 11
Brewer Setup ................................................................ 12
Parts Diagram CBS-1131XV+ ...................................... 14
Parts Diagrams CBS-1132XV+ .................................... 16
CBS-1131XV+ Tank Assembly ..................................... 18
CBS-1132XV+ Tank Assembly ..................................... 19
Wiring Diagrams ........................................................... 21
PHONE: (800) 338-2699 (US & CANADA)
(847) 719-3000
FAX: (847) 719-3001
EMAIL: sales@fetco.com
techsupport@fetco.com
PATENTS: WWW.fetco.com/patents
P166
REV:000
V+
®
CBS-1132-XV+
NOVEMBER 2017
 
 
 
 
 
 
 
 

Advertisement

Table of Contents
loading

Summary of Contents for Fetco CBS-1131-XV+

  • Page 1: Table Of Contents

    USER’S GUIDE & OPERATOR INSTRUCTIONS FETCO COFFEE BREWER: CBS-1130 EXTRACTOR ® ™ CBS-1131-XV+ CBS-1132-XV+ TABLE OF CONTENTS Specifications and Requirements ........2 Error Codes..............9     Rough-In Drawings ............2 Operator Training ............10     Electrical and Output Specifications ......3 Installation Guide ............
  • Page 2: Specifications And Requirements

    SKU E113172; E113173 Electrical installation, service and field conversion is to be made only by licensed electrician. Disconnect equipment from power supply before service Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166...
  • Page 3: Electrical And Output Specifications

    In all cases, any power cord installation is to be connected to a single branch circuit only Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166...
  • Page 4: Starting The Brew

    SAVE toggle to the SAVE- SAVE your changes screen appears YES screen screen YES screen and EXIT Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 4...
  • Page 5: Programming Menu Layout

    (3 or 6) A70 programming “A” menus. Make keys. See SAVE & any changes as EXIT in previous required table Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 5...
  • Page 6: A Program

    BATCH A5 position can be made active or inactive. Position A1 does not display this step BATCH A3 BATCH A6 Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 6...
  • Page 7: B General

    Use the formula above to determine the correct setting Set lower to increase volume, higher to decrease volume. See “PROGRAM” B5 and B6 For valve settings and calibration. Factory set brew valve flow rates are in liter/min Go to fetco.com for the latest versions of all information User Guide & Operator instructions...
  • Page 8: C Inputs

    Load From USB Will need reboot drive device. Disables all components in demo mode DEMO Mode DEMO ON/OFF Will need reboot Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 8...
  • Page 9: F Save & Exit

    Brew basket must be in place Insert brew basket into brewer rails to BSKT enable brewer This is a Insert Brew Basket SAFETY FEATURE Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 9...
  • Page 10: Operator Training

    5. Do not attempt to move hot beverage equipment once it is filled. Drain equipment before moving. 6. FETCO commercial coffee brewers prepare large amounts of coffee or tea in a single batch using very hot water 7. Commercial coffee brewers provides very hot water from the spray head, brew basket and faucet when it is pulled.
  • Page 11: Installation Guide

    4. Brewers in this series wire differently in regard to a neutral wire. Review the wire diagrams. 5. The electrical diagram is located in the User’s Guide and online at www.fetco.com. 6. Make sure of the tight grounding of the equipment and use the external ground bolt.
  • Page 12: Brewer Setup

    SELECT brewer model From PROGRAMMING (Page 4) go to position E2 Select model and SAVE (Page 9) Be certain to SAVE new settings Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017...
  • Page 13 Do not operate if unit has been submerged or saturated with water. Labels and warnings for hot beverage equipment For BACK PANEL of equipment (1046.00035.00) Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 13...
  • Page 14: Parts Diagram Cbs-1131Xv

    1401.00150.00 1086.00008.00 Field Wired E113182 1104.00086.01 1401.00150.00 1086.00008.00 Field Wired E113191 1104.00086.01 1401.00151.00 1086.00008.00 1063.00017.00 E113192 1104.00085.01 1401.00151.00 1086.00008.00 1063.00017.00 Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 14...
  • Page 15 TANK ASSY,1 X 2.3KW/120VAC, 1104.00083.01 TANK ASSY,1 X 1.5KW/120VAC, 1104.00086.01 TANK ASSY,1 X 3.0KW/240VAC *STANDARD-INCLUDED WITH ALL EQUIPMENT †-OPTION ACCESSORY FOR PURCHASE Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 15...
  • Page 16: Parts Diagrams Cbs-1132Xv

    E113264 1104.00057.01 1401.00158.00 1086.00029.00 E113266 1104.00052.01 1401.00158.00 1086.00029.00 E113268 1104.00057.01 1401.00158.00 1086.00029.00 E113291 1104.00052.01 1401.00149.00 1086.00029.00 E113292 1104.00057.01 1401.00149.00 1086.00008.00 Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 16...
  • Page 17 TANK ASSEMBLY, CBS-1132 XV+ 2 X 3KW/240VAC 1104.00057.01 TANK ASSEMBLY, CBS-1132 XV+ 2 X 2.3KW/240VAC *STANDARD-INCLUDED WITH ALL EQUIPMENT †-OPTION ACCESSORY FOR PURCHASE OR SELECT MODELS Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 17...
  • Page 18: Cbs-1131Xv+ Tank Assembly

    THERMOSTAT, SINGLE SHOT, 240V/40A 1083.00009.00 LOCKWASHER, #6 SCREW , INTERNAL TOOTH 1084.00010.00 NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED 1044.00004.00 LABEL, DANGER, HIGH VOLTAGE Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 18...
  • Page 19: Cbs-1132Xv+ Tank Assembly

    FITTING, BREW, GROMMET DESIGN 1023.00183.00 FITTING ELBOW 1023.00166.00 FITTING, COLD WATER INLET, GROMMET DESIGN 1044.00004.00 LABEL, WARNING-HIGH VOLTAGE 1022.00064.00 INSULATION TANK Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 19...
  • Page 20 SCREW PAN HD #*X9/16 LG SHEET METAL 1057.00038.00 DIAPHRAGM 1057.00040.00 PLUNGER 1057.00051.00 CONICAL SPRING 1024.00063.00 O-RING,LOWER 3 15/16" X 3/32" Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 20...
  • Page 21: Wiring Diagrams

    E113268 CBS-1132-XV+, 1Ph, L,N,PE, 2 X 2.3kW/240VAC, 230VAC, CE 1401.00078.00 E113291 CBS-1132-XV+, 1Ph, 2+G, 2 X 3.0kW/240VAC, 200-240VAC, INTL 1401.00085.00 Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 21...
  • Page 22 Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 22...
  • Page 23 Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 23...
  • Page 24 Go to fetco.com for the latest versions of all information User Guide & Operator instructions P166 NOVEMBER 2017 Page 24...
  • Page 25 End of Section Notes:...
  • Page 26 End of Section Notes:...

This manual is also suitable for:

Cbs-1132-xv+Extractor cbs-1130 v+ seriesExtractor cbs-1131-xv+Extractor cbs-1132-xv+