ETERNUS Web GUI Startup
3
1.
Open the Web browser on the PC terminal.
2.
Enter the following URL in the address bar of the Web browser.
http://192.168.1.1/
The login screen for ETERNUS Web GUI appears.
3.
To change the user interface language, click the [Option] button and select "English" or "Japanese" in
"Language".
4.
Enter the username and password.
Username: root
Password: root (by default)
After logging in, the Initial Setup screen of ETERNUS Web GUI appears.

Initial Setup

4
Perform the settings that are required before operation of the ETERNUS AF on the Initial Setup screen.
Perform the following settings according to the wizard
screen:
Set Storage System Name
Change User Password
Set Thin Provisioning
Register SED Authentication Key
Setup Network Environment
In the Setup Network Environment settings, set the IP
address of the MNT port to connect the ETERNUS AF to
the operation management LAN.
After the settings are complete, close the Web browser.
Establishing a Connection between the ETERNUS AF and the Operation Management LAN
5
Remove the LAN cable between the RMT port on Controller 0 and the PC terminal.
Connect the LAN cables of the MNT ports on Controller 0 and Controller 1 to the network of the customer.
Then start the web browser from the PC terminal that is connected to the network and log in to ETERNUS Web GUI
again with the IP address that is set in the Setup Network Environment settings. After login, the Overview screen
appears.

Firewall Settings

6
Set the firewall for each service.
1.
Click the [System] tab, click [Network] in [Category],
and then click [Setup Firewall] in [Action].
2.
Enable or disable each service. Make sure to disable
the ETERNUS DX Discovery function.
If the network environment is not set up,
IMPORTANT
the ETERNUS DX Discovery function is
enabled. Some functions are not available
when the ETERNUS DX Discovery function
is enabled for the MNT port. Make sure
to set up the network environment
and disable the ETERNUS DX Discovery
function.
FUJITSU Storage ETERNUS AF250 All-Flash Arrays Setup Guide
7
Copyright 2017 FUJITSU LIMITED
P3AG-1862-02ENZ0