Download Print this page

Chapter5 Output Protocol - Fujitsu PSN 900 Plus Operating Manual

Palm vein identification device (pvid)

Advertisement

Chapter5 Output Protocol

1. Wiegand port
The device is compatible with the Wiegand 26/34 output format. The contents
of the protocol are as follows:
1) "Site Code" is disabled
The Card + Palm Vein mode (1: 1 verification)
i. IC card: If the hexadecimal card number of an M1 S50 registration card is
74C3CAFB, then:
a) When it is outputted in the Wiegand 26 output format, the last 3 bytes of
the card number will be output, i.e., C3CAFB
b) When it is outputted in the Wiegand 34 output format, the last 4 bytes of
the card number will be output, i.e., 74C3CAFB
ii. For an ID card, the first 10 digits of the card number shown on the back of
the card will be read. The Wiegand output format is the same as that of the IC card.
The Palm Vein mode (1: N Identification)
In this mode, the door access control number is the output number. See
step5 in "Operation instructions" for the door access control number setting
rules.
The Pin Code + Palm Vein mode (1: 1 Verification)
The output method of this mode is the same as that of the Palm Vein
mode.
2) "Site Code" is enabled
If the hexadecimal card number of a registration card is 74C3CAFB and the
Site Code is set to be 200 (decimal), then:
a) If the output format is Wiegand 26, the last two bytes of the output Site
Code and card number is C8CAFB.
b) If the output format is Wiegand 34, the last two bytes of the output Site
Code and card number is 00C8CAFB.
c) If Corporate 1k is selected, the Site Code and card number will be output.
d) If CSN 32 is selected, the last two bytes of the Site Code and the card
number will be output without a parity bit: 00C8CAFB
2. Electric lock and exit switch ports
The device can be connected directly to the electric lock and exit switch. See
Wiring Instructions for the connection method.
3. Alarm / Doorbell ports
The device can be connected to an external alarm or doorbell. See Wiring
Instructions for the connection method.
4. The Door Opening Test function
If the device is connected to the door controller, the number sent for the
door-opening test is "1000000". A valid number "1000000" need to be registered on
the door controller before the door-opening test is carried out. If the device is
connected to the electric lock, the door can be opened directly.