Special Design Specifications
Thermal
Power On / Wake-Up Event

Environment Requirements

Temperature
Operating
Non-operating
Humidity
Operating
Non-operating
Vibration
Operating (unpacked)
Non-operating (packed)
Shock Operating
Drop Test
Definition
Test Standard
Package Cross Weight
KGs
0~9.1
9.1~18.2
18.2~27.3
27.3~45.4
10 drops: one corner, three edges, six surfaces
Chapter 1
+5°C ~ +35°C
-20°C ~ +60°C (packed), -10°C ~ +60°C (un-packed)
15% to 80% RH, non-condensing
10% to 90% RH, non-condensing at 40°C
5 ~ 500Hz, 2.20g RMS random, 10 minutes per axis in all three axes
5 ~ 500Hz, 1.09g RMS random, one hour per axis in all three axes
Half sine, 2g 11m seconds
The protection ability of packing & cushion must be capable of withstanding,
with no physical or functional damage, mechanical impact from height-specific
drops.
lbs
0~20
20~40
40~60
60~100
Dynamic fan speed control by hardware monitor
CPU over temperature (over 120
protection
Power Button: S1/S3/S4/S5
PS/2 Keyboard: S1/S3/S4
USB Keyboard: S1/S3/S4
RTC: S1/S5
LAN: S1/S3/S5
Modem (Ring): S1/S3/S5
Drop Height
CM
Inch
76
30
61
24
46
18
31
12
o
C) power off
Times of Drop
10
10
10
10
21

Hide quick links: