undo dot1x smarton switchid
Default
No SmartOn switch ID exists.
Views
System view
Predefined user roles
network-admin
Parameters
switch-string: Specifies the SmartOn switch ID, a case-sensitive string of 1 to 30 characters.
Usage guidelines
The device checks the SmartOn switch ID in each received EAP-Response/Notification packet. If the
switch ID is not the same as the switch ID on the device, the device stops the 802.1X authentication
process for the client that sends this packet.
Examples
# Set the SmartOn switch ID to abc.
<Sysname> system-view
[Sysname] dot1x smarton switchid abc
Related commands
display dot1x
dot1x smarton
dot1x smarton password

dot1x smarton timer supp-timeout

Use dot1x smarton timer supp-timeout to set the SmartOn client timeout timer.
Use undo dot1x smarton timer supp-timeout to restore the default.
Syntax
dot1x smarton timer supp-timeout supp-timeout-value
undo dot1x smarton timer supp-timeout
Default
The SmartOn client timeout timer is 30 seconds.
Views
System view
Predefined user roles
network-admin
Parameters
supp-timeout-value: Specifies the SmartOn client timeout timer in seconds. The value range is 10 to
120.
Usage guidelines
The SmartOn client timeout timer starts when the device sends an EAP-Request/Notification packet
to the client. If the device does not receive any EAP-Response/Notification packets from the client