Measured Values; A.10 Measured Values - Siemens Siprotec 7UM611 Manual

Multi-functional generator protection relay 7um61 series
Table of Contents

Advertisement

A Appendix

A.10 Measured Values

No.
Description
-
IL< under current (IL<)
-
Number of TRIPs (#of TRIPs=)
-
Number of TRIPs (#of TRIPs=)
-
Operating hours greater than (OpHour>)
601
I L1 (IL1 =)
602
I L2 (IL2 =)
603
I L3 (IL3 =)
605
I1 (positive sequence) (I1 =)
606
I2 (negative sequence) (I2 =)
621
U L1-E (UL1E=)
622
U L2-E (UL2E=)
623
U L3-E (UL3E=)
624
U L12 (UL12=)
625
U L23 (UL23=)
626
U L31 (UL31=)
627
Displacement voltage UE (UE =)
629
U1 (positive sequence) (U1 =)
630
U2 (negative sequence) (U2 =)
639
UE 3rd Harmonic Voltage Minimum (UE3h
Min=)
640
UE 3rd Harmonic Voltage Maximum (UE3h
Max=)
641
P (active power) (P =)
642
Q (reactive power) (Q =)
644
Frequency (Freq=)
645
S (apparent power) (S =)
650
UE 3rd harmonic (UE3h=)
660
Remaining Time for Switch ON (T Rem.=)
661
Threshold of Restart Inhibit (Θ REST. =)
765
(U/Un) / (f/fn) (U/f =)
766
Calculated temperature (U/f) (U/f th. =)
801
Temperat. rise for warning and trip (Θ/Θtrip
=)
802
Temperature rise for phase L1 (Θ/ΘtripL1=)
803
Temperature rise for phase L2 (Θ/ΘtripL2=)
804
Temperature rise for phase L3 (Θ/ΘtripL3=)
805
Temperature of Rotor (ΘR/ΘRmax =)
830
Senstive Earth Fault Current (IEE =)
831
3I0 (zero sequence) (3I0 =)
832
U0 (zero sequence) (U0 =)
857
Positive Sequence Minimum (I1Min=)
858
Positive Sequence Maximum (I1Max=)
874
U1 (positive sequence) Voltage Minimum
(U1Min=)
875
U1 (positive sequence) Voltage Maximum
(U1Max=)
408
Function
Set Points(MV)
-
-
Statistics
-
-
Statistics
-
-
SetPoint(Stat)
-
-
Measurement
134
147
Measurement
134
147
Measurement
134
147
Measurement
134
147
Measurement
134
147
Measurement
134
147
Measurement
134
147
Measurement
134
147
Measurement
-
-
Measurement
-
-
Measurement
-
-
Measurement
134
147
Measurement
134
147
Measurement
-
-
Min/Max meter
-
-
Min/Max meter
-
-
Measurement
134
147
Measurement
134
147
Measurement
134
147
Measurement
-
-
Measurement
-
-
Meas. Thermal
-
-
Meas. Thermal
-
-
Measurement
134
147
Meas. Thermal
-
-
Meas. Thermal
-
-
Meas. Thermal
-
-
Meas. Thermal
-
-
Meas. Thermal
-
-
Meas. Thermal
-
-
Measurement
134
147
Measurement
-
-
Measurement
-
-
Min/Max meter
-
-
Min/Max meter
-
-
Min/Max meter
-
-
Min/Max meter
-
-
IEC 60870-5-103
-
-
-
CFC
-
-
-
-
-
-
-
-
-
No
9
1
CFC
No
9
2
CFC
No
9
3
CFC
No
9
5
CFC
No
9
6
CFC
No
9
7
CFC
No
9
8
CFC
No
9
9
CFC
-
-
-
CFC
-
-
-
CFC
-
-
-
CFC
No
9
10
CFC
No
9
11
CFC
-
-
-
CFC
-
-
-
CFC
-
-
-
CFC
No
9
12
CFC
No
9
13
CFC
No
9
15
CFC
-
-
-
CFC
-
-
-
CFC
-
-
-
CFC
-
-
-
CFC
No
9
16
CFC
-
-
-
CFC
-
-
-
CFC
-
-
-
CFC
-
-
-
CFC
-
-
-
CFC
-
-
-
CFC
No
9
4
CFC
-
-
-
CFC
-
-
-
CFC
-
-
-
CFC
-
-
-
CFC
-
-
-
CFC
-
-
-
CFC
C53000-G1176-C127-3
Configurable in Matrix
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
CD
DD
7UM61 Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Siprotec 7um612

Table of Contents