Procedure
19.9
Editing the local variable table
You have the option of editing the local variable table of an INT block.
Insert local variable
If you have inserted new networks or operands, it may be necessary to insert new variables
in the local variable table of an INT block.
Name
Variable type
Data type
Comment
HMI sl Milling
Operating Manual, 06/2009, 6FC5398-7CP20-0BA0
1.
Ladder add-on tool is opened.
You have changed project data.
2.
Press the "PLC Stop" softkey if the PLC is in the run mode.
3.
Press the "Load to CPU" softkey to start the loading operation.
All data classes are loaded.
4.
When the PLC project has been loaded, press the "PLC Start" softkey
to switch the PLC to Run mode.
Freely assign.
Selection:
• IN
• IN_OUT
• OUT
• TEMP
Selection:
• BOOL
• BYTE
• WORD
• INT
• DWORD
• DINT
• REAL
Freely assign.
Ladder add-on tool
19.9 Editing the local variable table
455