Displaying Channel Guds - Siemens SINUMERIK 828D Operating Manual

Hmi sl milling
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

9.4

Displaying channel GUDs

Channel-specific user data
Like the GUDs, channel-specific user data are applicable in all programs for each channel.
However, unlike GUDs, they have specific values.
Definition
A channel-specific GUD variable is defined with the following:
● Keyword DEF
● Range of validity CHAN
● Data type
● Variable names
● Value assignment (optional)
Example
DEF CHAN REAL X_POS = 100.5
Proceed as follows
HMI sl Milling
Operating Manual, 06/2009, 6FC5398-7CP20-0BA0
1.
Select the "Parameter" operating area.
2.
Press the "User variable" softkey.
3.
Press the "Channel GUD" and "GUD selection" softkeys.
A new vertical softkey bar appears.
4.
Press the "SGUD" to "GUD6" softkeys if you want to display GUD 1 to
GUD 6 of the channel-specific user data.
- OR -
Press the "Continue" softkey and the "GUD7" to "GUD9" softkeys if
you want to display GUD 7 to GUD 9 of the channel-specific user
data.
User variables
9.4 Displaying channel GUDs
335

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de slSinumerik 840d sl

Table of Contents